Overpressure/Vacuum pump ÜVP/VP 218

 

- 7 - 

 

5.  Troubleshooting 

 

Fault 

1.

 

The  overpressure/vacuum  pump  stops 

and will not re-start. 

 

 

 

 
2

. The overpressure/vacuum pump heats up 

excessively. 
 
 

3

.  The  overpressure/vacuum  pump  is  very 

loud and emits rhythmic, metallic blows. 

 
 

4

.The  vacuum  pump  VP  218  does  not  build 

up  any  negative  pressure  on  the  monitoring 
chamber 
 
 

5.

  The  overpressure  pump  ÜVP  218  does 

not  build  up  any  overpressure  on  the  moni-
toring chamber 

 

 

Remedy 

1.

 

Switch  off  the  power  and  after  a  few 

minutes press the switch for the motor circuit 
breaker.  If  the  motor  circuit  breaker  triggers 
again  after  restarting,  contact  the  technical 
customer service department. 

1.1 

The motor coil has burned through; con-

tact a customer service agent. 

2.

  The  cylinder  head  seal  or  valve  is  dam-

aged.  Stop  the  overpressure/vacuum  pump 
immediately  and  contact  the  technical  cus-
tomer service department. 

3.

  The  slide  bush  or  the  bearing  bush  has 

seized  up.  Stop  the  overpressure/vacuum 
pump  immediately  and  contact  the  technical 
customer service department. 

4.

  Liquid  is  suctioned  and  the  liquids  barrier 

has  closed.  Empty  the  condensate  trap  and 
move  the  liquids  barrier  back  into  the  initial 
position (free passage) 

4.1

 Open the shut-off valve (fig. 1)

  

5.

 The liquid stop has blocked the suction 

line. Bring the floater inside the liquid stop 
back into normal position (free passage). 

5.1 

The pressure regulator at the pressure 

line is completely closed. Open the pressure 
regulator. 

 

Troubleshooting 

Содержание UVP 218

Страница 1: ...Documentation Overpressure Vacuum pump VP VP 218 Read the instructions before starting any work Issue 01 2019 Art no 605 642...

Страница 2: ...formation 3 1 1 Marking 1 2 Unpacking 1 3 Erection 1 4 Disposal 2 Safety 4 2 1 Intended use 2 2 Responsibility 2 3 Motor protection 3 Use 5 3 1 Installation 3 2 Switching on 4 Maintenance 6 5 Fault 7...

Страница 3: ...person and check whether the overpressure vacuum pump is complete and free of damage 1 3 Erection Always erect the pump with clearance of at least 50 cm to any obstruc tion which could obstruct the f...

Страница 4: ...uum pump if the mains cable is faulty or if the power connection is not established correctly Do not allow anyone to use the overpressure vacuum pump without hav ing received suitable training on use...

Страница 5: ...s equipped with a type CEE 7 plug connector If necessary have it replaced by specialist staff Always check whether the on off switch is in the 0 OFF position before you connect the plug connector fig...

Страница 6: ...According to 15 BetrSichV a plant in need of monitoring is only to be started after it has been subjected to a test before startup Furthermore recurring inspections according to 16 BetrSichV have to...

Страница 7: ...customer service department 1 1 The motor coil has burned through con tact a customer service agent 2 The cylinder head seal or valve is dam aged Stop the overpressure vacuum pump immediately and con...

Страница 8: ...rpressure Vacuum pump VP VP 218 22 01 2019 8 6 Figures On off switch Pressure gauge Shut off valve Figure 1 refers to VP 218 and VP 218 Motor circuit breaker Figure 2 refers to VP 218 and VP 218 Figur...

Страница 9: ...trap with integrated liquid stop Monitoring chamber connection vacuum 4 mm inner width for hose Figure 4 Figures Connection to interstitial space vacu um for hose 4 mm inner width Condensate trap with...

Страница 10: ...Machinery directive 2000 14 EC Noise emissions in the environment 2006 95 EC Low voltage directive 2004 108 EC EMC directive EN1012 1 Compressors and vacuum pumps Safety requirements Part 1 Air compre...

Страница 11: ..._____________________________________________________________________________ ______________________________________________________________________________________ ___________________________________...

Страница 12: ...Overpressure Vacuum pump VP VP 218 22 01 2019 12 Text Text Imprint SGB GmbH Hofstr 10 57076 Siegen Germany Phone 49 271 48964 0 E mail sgb sgb de Web www sgb de SGB GmbH 01 2019...

Отзывы: