The terminal block on the rear panel should be wired as detailed below:
The DIN-4P connector on the rear panel also used for power input, you can use an AC/DC adapter
with DIN-4P connector directly, recommends adaptor MS-180-18 or MS-180-24 as detailed below:
(OPTION)
MS-180-18
MS-180-24
Maximum output
18VDC/8.33A
24VDC/6.25A
*Ethernet Port Wiring
The PoE switch family supports one RJ-45 uplink (port 5 with PoE PD) and four RJ-45 ports (port
1~4 with PoE PSE) with automatic MDI/MDI-X crossover, auto-sense for speed and duplex for
10Base-T, 100Base-TX or 1000Base-T connection. Automatic MDI/MDI-X crossover allows you
to connect to other devices (switches, hubs, or workstations etc.), without regard to using
straight-through or crossover cabling.
Port 1 to 4 provides Power over Ethernet function that delivers DC power through the data pairs C
& D (pin 4,5 and pin 7,8) (mode B) to the PD. Port 5 provides Power Device function that receive
power from 4 pairs or 2 pairs Ethernet cable.
The following tables describe the wiring diagram of straight-through and crossover cabling. The
crossover cables simply cross-connect the transmit lines at each end to the receive lines at the
opposite end.