USER’S MANUAL
www.sfe-france.com
SFE-SW5G-25x4
5 Port PoE Switch & Extender
(Repeat Ethernet and PoE)
Страница 1: ...USER S MANUAL www sfe france com SFE SW5G 25x4 5 Port PoE Switch Extender Repeat Ethernet and PoE...
Страница 2: ...er s Manual SFE SW5G series 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port Wiring PD Port Wiring Network Application 3 Technical Specification 3 3 3 5 7 9 10...
Страница 3: ...IEEE802 3at standard to receive and deliver both Ethernet data and DC power through the traditional UTP or STP cable The PoE Switch can extend Ethernet data and DC power up to 200 meters This manual w...
Страница 4: ...000Mbps but no communication activity is detected Green Blinking This port is transmitting to or receiving package from another device at 1000Mbps Yellow A network device is detected 10Mbps or 100Mbps...
Страница 5: ...ut Output Wattage Remark E F S SW5G25A4 12 36VDC P3 44 57VDC POE 56VDC 1236 0 625A 35W port 802 3at E F S SW5G25B4 12 36VDC P3 44 57VDC POE 56VDC 4578 0 625A 35W port 802 3at E F S SW5G25D4 12 36VDC P...
Страница 6: ...t cable as detailed below Mode A SFE SW5G25A4 Data pair A plus V on line 1 and 2 Data pair B plus V on line 3 and 6 Data pair C on line 4 and 5 Data pair D on line 7 and 8 Mode B SFE SW5G25B4 Data pai...
Страница 7: ...I MDI X crossover auto sense for speed and duplex for 10Base T 100Base TX or 1000Base T connection Automatic MDI MDI X crossover allows you to connect to other devices switches hubs or workstations et...
Страница 8: ...ect an Ethernet cable into any switch port and connect the other side to your attached device The Link Act LED green or yellow will light up when the cable is correctly connected Refer to the LED Indi...
Страница 9: ...ort Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport NegativeVport 7 Negative Vport 8 Negative Vport Be sure the twisted...
Страница 10: ...midspan and provide power to the PD which follows the IEEE 802 3af at standard in the network The PoE Switch can be installed in a more appropriate position for better performance to extend Ethernet...
Страница 11: ...tion Switch technology store and forward Protocols CSMA CD Flow control IEEE802 3x full duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T 14880pp...
Страница 12: ...n IEEE802 3af IEEE802 3at 2 event classification signaling PoE protection Over temperature over current over under voltage LEDs Link Activity Green ON Green Blinking 1000Mbps Yellow Yellow Blinking 10...
Страница 13: ...ion on data pairs Signal Operating Voltage Data 5V Clamping Voltage Data 16 5V I PP 5A t p 8 20 s I O pin to GND Peak Pulse Current 20A tp 8 20 s Pin Protected All 8 pin protected data input Max Shut...