SERVICING
11
REMEDY
• Clean or replace vent/valve.(48).
• Remove the motor and soak it in
suitable descalent (vinegar).
• Remove limescale or remove
motor and clean.
• Modify the installation.
• Remove the motor and scrape
off the limescale or soak the
motor in suitable descalent
(vinegar).
• Remove the motor block, take
out foreign object through the
opening in motor cover (22). If
unsuccessful, dismantle.
• Press strongly on the push
button.
• Replace the pressure switch (49).
• Call a service engineer.
• Call a service engineer.
• Clean the filter.
• Open the stopcock.
• Replace the electrovalve (28).
POSSIBLE CAUSE
• The one way vent/valve (48) is
not operating normally
• The discharge pipe is blocked
with limescale
• The grille (62) is blocked with
tissue or limescale.
• The discharge height is more
than the spec.
• Limescale has narrowed the
discharge pipe.
• A foreign object has entered the
blade/ grille area. (65/62)
• The push button (11) has not
been pressed hard enough.
• The button (11) is defective
(verify by detailing it from the
transparent tube and blow it to
see if the motor activates).
• The activating pressure switch
(49) is defective.
• The timer (46) is defective.
• Water inlet filter on electrovalve
(28) blocked.
• The stopcock is shut.
• The electrovalve (28) is defective.
SYMPTOM
• The flushing cycle activates
normally, the motor turns, but
the water leaves the pan slowly
or not at all.
• The flushing cycle activates
normally, but after any cycle a
little water stays into the pan
• The motor activates with a
mechanical/rattling sound.
• The flushing cycle does not
engage on pressing the
activating button. (11)
• The cycle starts, but water enters
into the pan too slowly.
• The cycle starts, but no water
enters into the pan
Warning - Always disconnect the electricity supply
before attempting any work on the SANICOMPACT
®
COMMISSIONING THE UNIT
Connect the toilet to the electrical supply. Open the water
supply completely in order to have an efficient rinsing stage.
To activate the flushing cycle, push the button mounted on the
rear edge of the pan. Throw a few toilet paper sheets in the
bowl and start the cycle again.
Wash basin option :
turn on the washbasin tap, and the
motor will activate automatically. Check the watertightness of
all connections.
Note:
the basin tap should be watertight. Any dripping will
cause the motor to activate in regular short bursts.
8
USE
SANICOMPACT
®
does not require any special
maintenance.
WARNING 1:
The SANICOMPACT
®
range should only be
used for the evacuating of normal human waste, toilet
paper and household WC cleansers.
Damage may occur to the machine if the following are
disposed of via the WC; Cotton wool, tampons, sanitary
towels, wet wipes, kitchen towels, condoms as well as
other fabric or hard objects. Solvents, acids and other
chemicals can also cause damage to the unit, and will
invalidate the warranty.
WARNING 2:
In case of a long electrical shut off (vacation,
strike, work being done on the electrical or water supply)
close the water supply.
9
CLEANING AND REMOVAL OF SCALE
• To clean the bowl and remove scale, use regular
bathroom cleaning products.
• To avoid accumulations of scale inside the motor,
we advise you to clean it regularly.To do so:
• Shut off the water supply
• Flush the toilet
• Pour one litre of bathroom cleaning product
(or vinegar) in the bowl
• Leave sit for a few hours
• Open water supply and flush
• the toilet several times.
The frequency of the cleaning depends on the hardness of
the water in your area. We advise you to do it at least once
a year.
Do not put any acids, caustic sodas or solvents down
SANICOMPACT
®
.
10
REMOVAL
12
GUARANTIE
The
SANICOMPACT
®
range is guaranteed for 2 years,
subject to correct installation and usage.
13
In the unlikely case of product malfunction, repairs may be done
by yourself or by our authorized repair shops. For more information
please call SFA customer service or call an authorized repair center.
ANY SERVICE WORK INVOLVING ELECTRICAL COMPONENTS SHOULD ONLY BE CARRIED OUT
BY A RECOGNISED SERVICE ENGINEER
REMOVING THE BOWL
Unplug power supply
• Shut off water supply and
disconnect.
• Unscrew the bracket screws
on the back of the toilet .
• Release the discharge pipe
from discharge elbow .
• Incline the toilet frontwards and
drain residual water into a
bucket/ tub in order to empty
the toilet.
REMOVING THE MOTOR
• Remove the side screws
which hold the motor case.
• Remove the clear hose from the
pneumatic push button (11).
• Remove the clear water supply
hose (6).
• Unscrew the gear-clamp (20)
between the elbow and the case
of the motor.
• Remove the motor from the
bottom of the toilet.
OPENING THE MOTOR
• Remove the screws to release
the lid on the motor case (30).
• Check that the shaft is rotating
properly.
Warning!
the knives are very
sharp (64).
• Proceed with cleaning if needed.
• Grease the cover gasket (23)
before reinstalling.
NORM
•
SANICOMPACT
®
conforms to EN 12050-3.
Lifting plant for wastewater containing faecal matter for
limited applications.
7