SFA SANICOMPACT LUXE C3 Скачать руководство пользователя страница 5

SERVICING

11

REMEDY

• Clean or replace vent/valve.(48).

• Remove the motor and soak it in

suitable descalent (vinegar).

• Remove limescale or remove

motor and clean.

• Modify the installation.

• Remove the motor and scrape

off the limescale or soak the

motor in suitable descalent

(vinegar).

• Remove the motor block, take

out foreign object through the

opening in motor cover (22). If

unsuccessful, dismantle.

• Press strongly on the push 

button.

• Replace the pressure switch (49).

• Call a service engineer.

• Call a service engineer.

• Clean the filter.

• Open the stopcock.

• Replace the electrovalve (28).

POSSIBLE CAUSE

• The one way vent/valve (48) is

not operating normally

• The discharge pipe is blocked

with limescale

• The grille (62) is blocked with 

tissue or limescale.

• The discharge height is more

than the spec.

• Limescale has narrowed the

discharge pipe.

• A foreign object has entered the

blade/ grille area. (65/62)

• The push button (11) has not

been pressed hard enough.

• The button (11) is defective 

(verify by detailing it from the

transparent tube and blow it to

see if the motor activates).

• The activating pressure switch

(49) is defective.

• The timer (46) is defective.

• Water inlet filter on electrovalve

(28) blocked.

• The stopcock is shut.

• The electrovalve (28) is defective.

SYMPTOM

• The flushing cycle activates 

normally, the motor turns, but

the water leaves the pan slowly

or not at all.

• The flushing cycle activates 

normally, but after any cycle a

little water stays into the pan

• The motor activates with a

mechanical/rattling sound.

• The flushing cycle does not

engage on pressing the 

activating button. (11)

• The cycle starts, but water enters

into the pan too slowly.

• The cycle starts, but no water

enters into the pan

Warning - Always disconnect the electricity supply 

before attempting any work on the SANICOMPACT

®

COMMISSIONING THE UNIT

Connect the toilet to the electrical supply. Open the water 
supply completely in order to have an efficient rinsing stage.
To activate the flushing cycle, push the button mounted on the
rear edge of the pan. Throw a few toilet paper sheets in the
bowl and start the cycle again.

Wash basin option :

turn on the washbasin tap, and the

motor will activate automatically. Check the watertightness of
all connections.

Note:

the basin tap should be watertight. Any dripping will

cause the motor to activate in regular short bursts.

8

USE

SANICOMPACT

®

does not require any special 

maintenance.

WARNING 1: 

The SANICOMPACT

®

range should only be

used for the evacuating of normal human waste, toilet
paper and household WC cleansers. 
Damage may occur to the machine if the following are
disposed of via the WC; Cotton wool, tampons, sanitary
towels, wet wipes, kitchen towels, condoms as well as
other fabric or hard objects. Solvents, acids and other 
chemicals can also cause damage to the unit, and will
invalidate the warranty.

WARNING 2:

In case of a long electrical shut off (vacation,

strike, work being done on the electrical or water supply)
close the water supply.

9

CLEANING AND REMOVAL OF SCALE

• To clean the bowl and remove scale, use regular

bathroom cleaning products. 

• To avoid accumulations of scale inside the motor,

we advise you to clean it regularly.To do so:

• Shut off the water supply

• Flush the toilet

• Pour one litre of bathroom cleaning product 

(or vinegar) in the bowl

• Leave sit for a few hours

• Open water supply and flush 

• the toilet several times.

The frequency of the cleaning depends on the hardness of

the water in your area. We advise you to do it at least once

a year.

Do not put any acids, caustic sodas or solvents down

SANICOMPACT

®

.

10

REMOVAL

12

GUARANTIE

The

SANICOMPACT

®

range is guaranteed for 2 years, 

subject to correct installation and usage.

13

In the unlikely case of product malfunction, repairs may be done 

by yourself or by our authorized repair shops. For more information

please call SFA customer service or call an authorized repair center.

ANY SERVICE WORK INVOLVING ELECTRICAL COMPONENTS SHOULD ONLY BE CARRIED OUT 

BY A RECOGNISED SERVICE ENGINEER

REMOVING THE BOWL 

Unplug power supply 

• Shut off water supply and 

disconnect.

• Unscrew the bracket screws 

on the back of the toilet .

• Release the discharge pipe 

from discharge elbow .

• Incline the toilet frontwards and

drain residual water into a 
bucket/ tub in order to empty 
the toilet. 

REMOVING THE MOTOR

• Remove the side screws 

which hold the motor case.

• Remove the clear hose from the

pneumatic push button (11).

• Remove the clear water supply

hose (6).

• Unscrew the gear-clamp (20) 

between the elbow and the case
of the motor.

• Remove the motor from the 
bottom of the toilet.

OPENING THE MOTOR

• Remove the screws to release

the lid on the motor case (30).

• Check that the shaft is rotating

properly.

Warning!

the knives are very

sharp (64).
• Proceed with cleaning if needed.
• Grease the cover gasket (23)

before reinstalling.

NORM

SANICOMPACT

®

conforms to EN 12050-3.

Lifting plant for wastewater containing faecal matter for
limited applications.

7