XIV
AFTER SALES SERVICE
ln the unlikely event of a failure or
malfunction, please call our after sales
service department.
WARNING:
Always disconnect the electric
supply before attempting any work on the
SANICOMPACT COMFORT
®
.
XIII
CARE OF YOUR
SANICOMPACT COMFORT
®
• N o r m a l h o u s e h o l d b l e a c h e s /
WC cleaners can be used with a
SANICOMPACT COMFORT
®
.
• To avoid the build up of lime scale in
the unit, use the following procedure:
• disconnect the power supply to the
unit,
XV
ADVICE
PIPE SUPPORTS
All sanitary pipe work must be
supported, in accordance with the pipe
manufacturer’s recommendations. Avoid
dipping or trapping, which may cause
the build up of residual “solids” and sub-
sequent blockage.
BENDS
Where possible long sweeping bends
should be used. Do not use short elbows.
If sweeping 90° elbows are not available
use two 45° elbows to make a 90° turn.
PIPE WORK
All pipe work should be either copper,
PVC or CPVC (Do not use flexible pipes).
Hangers should not be less than four feet
apart to prevent pipe rattling.
DISCHARGE
Never discharge directly into an open
drain, fixture, manhole or rainwater
drainpipe. It is illegal for it constitutes
a health hazard. Direct connections into
sanitary waste systems only, shall be
acceptable.
FREEZING
Ensure all pipe work susceptible to
freezing is adequately insulated or
heated. In unheated buildings, the
toilet, piping and macerating unit
must be properly winterized with “RV
or plumbers” anti-freeze or drained
completely.
• pour 1 gallon (3 to 4 liters) of water
mixed with a strong solution of descaler
into the bowl,
• leave it to stand for 1 or 2 hours, then
re-connect the electric supply,
• flush several times to clear.
The frequency of this operation will
depend on the hardness of the water in
your locality. We would recommend this
be done about twice a year.
ELECTRICITY
Before attempting any maintenance or
servicing, the unit must be disconnected from
the power source. The macerating system
must be connected to a Ground Fault Circuit
Interrupter.
VERTICAL INSTALLATION FIRST
If vertical lift is required, this must precede the
horizontal pipe run.
EASY ACCESS
The unit should be accessible and removable
in the event of maintenance being required.
During the installation a full-port ball valve
should be installed at the base of any vertical
discharge pipe work from the unit to allow easy
service of the unit.
GRAVITY FALL
The unit accepts wastewater by gravity; it does
not “vacuum” in water. All inlet pipe work must
have a positive gravity fall, (1/4» per foot). All
horizontal piping from the macerating unit
must also have a positive gravity fall to allow
free drainage when the pump stops.
NO DIAGONAL “UPHILL”
PIPE RUNS
All discharge pipe work from the unit should
run either directly vertical upwards from it or
in a horizontal plane (with a small gravity flow)
to the point of discharge. Pipe work should not
be installed with diagonal upward slope from
the unit to the point of discharge.
3
Содержание Sanicompact comfort
Страница 2: ...1 2 4 7 9 Ft max Ø 1 Ø 1 Ø 1 1 2 3 5 1 2 Ø 1 1 4 SANICOMPACT COMFORT 120V 60 Hz 0 5 HP ...
Страница 5: ...15 16 19 18 17 20 21 Ø 1 G J I H Ø 1 1 4 I N J SANICOMPACT COMFORT 120V 60 Hz 0 5 HP ...
Страница 7: ...SANICOMPACT COMFORT 120V 60 Hz 0 5 HP ...
Страница 18: ...NOTES 10 ...
Страница 19: ...NOTES 11 ...
Страница 20: ...NOTES 12 ...