Digital Weighing Indicator
SI 4200
- 30 -
Rounding Off Selection (Counting)
F29
●
0
Rounding Off Use
1
Rounding Off Not use
■
Communication Mode setting (Serial Port 1. - Standard installed port)
Parity Bit selection Mode
F30
●
0
No Parity
1
Odd Parity
2
Even Parity
Serial Communication Speed selection
F31
0
2,400bps
1
4,800bps
●
2
9,600bps
3
14,400bps
4
19,200bps
5
28,800bps
6
38,400bps
7
57,600bps
8
76,800bps
9
115,200bps
DATA Transference Method selection
F32
●
0
Simplex Mode / Stream Mode
1
Duplex Mode / Command Mode
Print port selection (Under F32-01 setting, only)
F33
●
0
Same port as using for Command Mode.
1
The other port.
“Check-Sum” detection selection (Under F32-01 setting, only)
F34
●
0
Check-Sum data will not be included on transferred data.
1
Check-Sum data will be included on transferred data.
Serial Port Application Selection (Under F32-00 setting, only)
F35
●
0
DATA Transference purpose
1
Printing purpose (Serial Printer)
DATA Transference Mode selection (Under F32-00, F35-00 setting, only)
F36
●
0
Stream Mode : Weighing Data will be transferred continuously.
1