Weighing Mode 1. – Limit Mode (F21-01 setting)
– Checker mode will be operated basis on Quantity, not Weight value.
-
This Flow Chart is based on High”/”Low” range is Zero
1. Set Value
SP1, SP2, Free Fall,
(SP2 > SP1)
, (
SP2 – Free Fall > SP1)
※
If the setting conditions are not satisfied,
“E”
symbol displayed and you can process the weighing.
2. Low / High output (LOW/HIGH value must be smaller than Max. Capacity.)
LOW relay output : Relay output, when the current weight is less than (FINAL-LOW) value.
HIGH relay output : Relay output, when the current weight is more than (FINAL+HIGH) value.
3. Relay Output
Relay
Contents
Relay
Contents
SP1
Reach to PRE 1 Set : ON
Under than PRE 1 : OFF
Low
Current weight < FINAL-LOW : ON
SP2
Reach to FINAL Set : ON
Under than FINAL : OFF
High
Current weight > FINAL+HIGH : ON
Empty
Within “Empty Range” : ON
SP1
SP2
FINISH
Weight
Empty
TARE
SP1
SP2
FINISH
UNDER
OVER
EMPTY
Out 1
Out 2
Out 3
Out 4
Out 5
Out 6