![Sewha SI 410 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/sewha/si-410/si-410_user-manual_1250426033.webp)
- 33 -
SI 410 WEIGHING INDICATOR
◆Weighing mode 2. – Limit mode 6 (B Dry contact) - User’s choice relay output 1
(Function 223-02)
- relay output order is selectable by user
Time
Time
Contents
t1
Finish Relay Output Delay Time (Function 239)
When Function 103-3 or 103-6, save the date after t1 time.
t2
Finish Relay Output Time (Function 240)
Relay output
Relay
Condition
Relay
Condition
OUT 1
Current weight < SP1 (ON)
Current weight ≥ SP1 (OFF)
OUT 4
Current weight < SP4 (ON)
Current weight ≥ SP4 (OFF)
OUT 2
Current weight < SP2 (ON)
Current weight ≥ SP2 (OFF)
OUT 5
After SP2
After t1 set time
During t2 set time (ON)
OUT 3
Current weight < SP3 (ON)
Current weight ≥ SP3 (OFF)
OUT 6
Within near zero range (Function
201) (ON)
WEIGHT
Near Zero
Zero
Tare Input