35
5 SePem 01 Master
Radio times
The settings under
Radio times
determine when and for how
long a
logger
is ready to exchange data with the
Master
(
radio
time frame
). The length of time between two transmission pulses
is specified under
Patrol style
.
LOGGER CONFIGURATION
Radio times
Days
SU MO TU WE TH FR SA
●
Days of the week on which the radio time
frame will be open
●
The ticks can be set or removed using the jog
dial
Time
Hrs
(hour: minutes)
●
Time of day at which the radio time frame will
be open
Duration
h
(hours)
●
Duration of radio connection (1-23h)
Patrol
style
DRIVE > SLOW DRIVE > WALK > STATIC
●
Type of patrol
● specifies the length of time between two
transmission pulses
●
DRIVE
: transmission pulse
5 s
equivalent to vehicle at approx. 30 km/h
●
SLOW DRIVE
: Transmission pulse
10 s
equivalent to vehicle at less than 10 km/h or
stop-and-go traffic
●
WALK
: Transmission pulse
30 s
equivalent to foot patrol
●
STATIC
: Transmission pulse
60 s