background image

1

Aufbau des / Design of the :   

DUOPHON®

60

40

80

20

100

0

+ -

+  -

+  -

1

2

3

4

1.1

1.3

1.4

6

1.2

5

8

9

10

11

12

13

13.1

13.2

13.3

13.4

14

15

16

17

7

6

Содержание Duophon

Страница 1: ...Anleitung Wir sichern Lebensqualit t Operating Instructions Betriebs 100533 60 40 80 20 100 0...

Страница 2: ...Ihre Hermann Sewerin GmbH Robert Bosch Stra e 3 D 33334 G tersloh 0 52 41 9 34 0 FAX 0 52 41 9 34 4 44 http www sewerin com Measurable success by Sewerin equipment You settled on a precision instrume...

Страница 3: ...1 Aufbau des Design of the DUOPHON 60 40 80 20 100 0 1 2 3 4 1 1 1 3 1 4 6 1 2 5 8 9 10 11 12 13 13 1 13 2 13 3 13 4 14 15 16 17 7 6...

Страница 4: ...2 NOTIZEN NOTES...

Страница 5: ...3 DUOPHON Betriebsanleitung Seite 5 24 Operating Instructions page 25 44 100533 01 30 01 1996...

Страница 6: ...4 NOTIZEN NOTES...

Страница 7: ...5 Das SEWERIN Wasserlecksuch Leitungsortungssystem DUOPHON...

Страница 8: ...r ber soweit das Ger t von Personen die nicht dem SEWERIN Service angeh ren unsachgem gewartet oder instandgesetzt wird oder wenn eine Handhabung erfolgt die nicht der bestimmungsgem en Verwendung ent...

Страница 9: ...orgung 13 5 0 Hinweise f r die praktische Arbeit 14 5 1 DUOPHON f r die Wasserlecksuche 14 5 1 1 Vorortung mit dem K rperschallmikrofon 14 5 1 2 Lokalisation mit dem Bodenmikrofon 15 5 2 DUOPHON f r d...

Страница 10: ...Indirekt Dauerton 2 Leistungssteller EinstellenderSendeleistung 3 Ein Aus Taster Sender ein ausschalten 4 Kontroll LED Anzeige von Sender eingeschaltet Sender laden 5 Tragegriff 6 galvanischer Ausgang...

Страница 11: ...rperschall Boden mikrofon oder Suchspule 16 Anzeige Signalst rke 17 Anzeige Batteriekapazit t 1 1 Der Verwendungszweck Das DUOPHON System kann sowohl f r die elektro akustische Wasserlecksuchealsauchf...

Страница 12: ...er Tragetasche DUOPHON als Leitungsortungsger t DUOPHON Empf nger Suchspule FS 3A Kopfh rer DUOPHON Sender Steckernetzger t Auto Anschlu adapter Kabelsatz Tragetasche DUOPHON als Wasserlecksuch und Le...

Страница 13: ...nuten aus Akku leer oder Sender ausgeschaltet Die gew nschte Betriebsart stellen Sie ber den Drehschalter Pos 1 ein Mit dem Leistungssteller Pos 2 kann die Sendeleistung in den Stufen 25 50 75 und 100...

Страница 14: ...rke wird am Instrument angezeigt Pos 16 IndieserBetriebsartistdieFeinabstimmung Pos 12 ohneFunktion Soll der Empf nger zur Leitungsortung benutzt werden bringen Sie den Drehschalter Pos 13 in Position...

Страница 15: ...l ber die Kfz Batterie Auto Anschlu adapter 12 V 12 V bzw 24 V 12 V Nach ca 14 Stunden ist der Akku vollgeladen und der Sender schaltet vom Ladebetrieb in den Pufferbetrieb Dort kann das Ger t bis zum...

Страница 16: ...hrleitung bertragen werden K rperschall k nnen an zug nglichen Leitungsteilen oder Armaturen vorgeortet werden vgl Abb 1 Abb 1 Vorortung mit dem K rperschallmikrofon Dazu gehen Sie folgenderma en vor...

Страница 17: ...den Armaturen mit den lautesten Ger usch intensit tenwirddieTrasseinregelm igenAbst nden abgehorcht vgl Abb 2 Abb 2 Lokalisation mit dem Bodenmikrofon Dazu gehen Sie folgenderma en vor Bodenmikrofon D...

Страница 18: ...die zu ortende Leitung direkt besendet werden vgl Abb 3 stellen Sie eine Verbindung zwischen Sender Erdspie und zwischen Sender Leitungsarmatur her Pos 6 Der Erdspie sollteineinigenMeternEntfernungrec...

Страница 19: ...Drehschalter Pos 13 in Position 13 3 bringen und Mikrofontaste Pos 8 dr cken bei stromf hrenden Kabeln und kathodisch gesch tzten Leitungen Suchspule ber die Trasse f hren Die Suchspule nicht um den H...

Страница 20: ...tellung eingerastet vgl Abb 6 Abb 6 Maximummethode Das magnetische Feld erzeugt den abgebildeten Signalverlauf und kann wieder ber die Anzeige Pos 16 und den Kopfh rer Pos 9 kontrolliert werden Hier w...

Страница 21: ...en Der Abstand zwischen der Trasse und einem Minimum entspricht dann der Verlegungstiefe Zum Ausgleich von nicht ganz kreisf rmigen Magnetfeldern ergibt sich die Verlegungstiefe als der halbe Abstand...

Страница 22: ...5 Watt galvanisch Stromversorgung NiCd Akku Laden 12 V integrierter Timer Puffer technik Schutzabschaltung und Zustandsanzeige Betriebszeit max 12 h Impulston max 6 h Dauerton Betriebstemperatur 10 bi...

Страница 23: ...tung 50 100 Hz passiv Stromkabel oder kathodisch gesch tzte Leitungen 9 95 kHz Senderfrequenz Stromversorgung 8x1 5VBabyzellen R14 LR14 Betriebszeit 100 h Betriebstemperatur 10 bis 40 Celsius Lagertem...

Страница 24: ...22 Konformit tserkl rung DUOPHON...

Страница 25: ...23 Konformit tserkl rung DUOPHON...

Страница 26: ...24 Notizen...

Страница 27: ...25 The SEWERIN System for Water Leak Detection and Pipe Location DUOPHON...

Страница 28: ...er or user in all cases where the device has been incorrectly serviced or repaired by persons other than members of the SEWERIN service team and when it is operated in a way which does not correspond...

Страница 29: ...Tips for Field Work 32 5 1 Water Leak Detection with the DUOPHON 32 5 1 1 Prelocation with the Bodysound Microphone 32 5 1 2 Localization with the Ground Microphone 33 5 2 Pipe Location with the DUOPH...

Страница 30: ...tone 2 Output Control Selection of Transmitter Output 3 On Off Key Switching Transmitter On or Off 4 Control LED Indication of Transmitter switched on Transmitterrequirescharging 5 Carrying handle 6 G...

Страница 31: ...und or Ground Microphone or Search Coil 16 Indication of Signal Intensity 17 Indication of Battery Capacity 1 1 Purpose The DUOPHON System is designed for the electro acoustic water leak detection as...

Страница 32: ...s Carrying Bag Pipe Locator DUOPHON with Receiver Search Coil Type FS 3A Earphones Transmitter Power Supply Set Car Adapter Set of Cables Carrying Bag DUOPHON Combination for Water Leak Detection and...

Страница 33: ...st 5 minutes off Batterydischargedortransmitterswitched off The required operating mode is adjusted by the rotary switch Item 1 With the output control Item 2 the transmission output can be adjusted t...

Страница 34: ...ndintensitywillbedisplayedontheinstrument Item 16 In this operating mode the fine tuning Item 12 has no function When the receiver shall be used for pipe location the rotary switch Item 13 must be in...

Страница 35: ...Set 230 V 12 V or from the car battery Car Adapter 12 V 12 V or 24 V 12 V After about 14 hours charging the battery is fully charged and the transmitterswitchesfromchargingtobuffering Thetransmitterca...

Страница 36: ...d by the pipeline bodysound can be prelocated at accessible parts of the pipe or on fittings Refer to Pict 1 Pict 1 Prelocation with the bodysound microphone Proceed as follows Screw tip and extension...

Страница 37: ...en fittings where the highest sound intensities have been measured the ground microphone will be placed down in regular distances Refer to Pict 2 Pict 2 Localization with the Ground Microphone Proceed...

Страница 38: ...gized directly Refer to pict 3 a connection must be made between the transmitter earth plug and between the transmitter and a pipe fitting Item 6 The earth plug should be pushed into the soil within a...

Страница 39: ...tem 13 into position 13 3 and push microphone key Item 8 when power carrying cables and cathodically protected pipes are concerned Move search coil along the pipe s trace Don t let the search coil swi...

Страница 40: ...ed into 90 degree position refer to pict 6 Pict 6 Maximum method The magnetic field of force produces a course of signals as pictured This can also be controlled via the meter Item 16 and the earphone...

Страница 41: ...side of the pipeline The distance between the trace and one of the minima is the depth where the pipe has been laid In case the magnetic fields of force are not exactly circular half the distance betw...

Страница 42: ...vanic Power supply NiCd batteries Charging 12 V integrated timer buffering technique safety switch off and indication of the state Operating time max 12 h pulse tone max 6 h constant tone Operating te...

Страница 43: ...0 Hz passive power carrying cables or cathodically protected pipelines 9 95 kHz transmitting frequency Power supply 8 1 5 V Dry Cells R14 LR14 Operating time 100 h Operating temperature 10 40 Celsius...

Страница 44: ...42 Declaration of Conformity DUOPHON...

Страница 45: ...43 Declaration of Conformity DUOPHON...

Страница 46: ...44 Notes...

Страница 47: ...Robert Bosch Stra e 3 D 33334 G tersloh Telefon 49 0 52 41 9 34 0 Telefax 49 0 52 41 9 34 4 44 Hermann Sewerin GmbH http www sewerin com...

Отзывы: