8 Appendix
│
19
8.1.2
Tapper
Max. operating time
80 h
Min. operating time
4.5 h
Control pulses
Knock period
16 ms to 80 ms (power)
Knock frequency
0.4 s – 1.6 s (centre position = 1 s)
8.1.3
Stopper (optional)
Max. operating time
11 h
Min. operating time
7.5 h
Control pulses
Pulse duration
120 ms (non-adjustable)
Pulse frequency
1 s – 1.6 s
8.1.4
AC/DC adapter L
Input
100 – 240 V~ / 50 Hz / 1 A
Output
12 V= / 5 A
8.1.5
Remote control (optional)
Range
30 m – 300 m
8.2
Accessories
Part
Order number
Standpipe DN 80 / Storz-C
SA03-Z1000
Vehicle cable
L
12 V =
ZL05-10200
8.3
Declaration of conformity
Hermann Sewerin GmbH hereby declares that the
CG 50
gener-
ator fulfils the requirements of the following guidelines:
●
2011/65/EU
●
2014/30/EU
The complete declaration of conformity can be found online.