108
Manual – MOVIDRIVE® MDX60B/61B Communication and Fieldbus Unit Profile
7
Setting the inverter parameters
SEW Unit Profile
Example: Invalid
parameter setting
An incorrect index was entered when executing a read or write service.
0x08
00
0x00
No Error
0x10
Illegal Index
0x11
Not yet implemented
0x12
Read only
0x13
Parameter Blocking
0x14
Setup runs
0x15
Value too large
0x16
Value too small
0x17
Required Hardware does not exist
0x18
Internal Error
0x19
Access only via RS485 (via X13)
0x1A
Access only via RS485 (via XT)
0x1B
Parameter protected
0x1C
"Controller inhibit" required
0x1D
Value invalid
0x1E
Setup started
0x1F
Buffer overflow
0x20
"No Enable" required
0x21
End of File
0x22
Communication Order
0x23
"IPOS Stop" required
0x24
Autosetup
0x25
Encoder Nameplate Error
0x29
PLC State Error
MOVILINK
®
Additional code
Error class
High
Low
Description
Code (hex)
Meaning
Error class
0x08
Other
Error code
0x00
-
Add. code high
0x00
-
Add. code low
0x10
Illegal Index