86
Assembly and Operating Instructions – Gear Units R..7, F..7, K..7, K..9, S..7, SPIROPLAN® W
6
Inspection/maintenance intervals
Inspection/Maintenance
•
Strict adherence to the inspection and maintenance intervals is absolutely necessary
to ensure safe working conditions.
•
Before releasing shaft connections, make sure that there are no active torsional
moments present (tensions within the system).
•
Prevent foreign bodies from entering the gear unit during maintenance and inspec-
tion work.
•
Do not clean the gear unit with a high-pressure cleaning system as water might enter
the gear unit and the seals might be damaged.
•
Perform safety and function tests following all maintenance and repair work.
6.2
Inspection/maintenance intervals
The following table lists the obligatory intervals and the corresponding measures:
Time interval
What to do?
•
Every 3,000 hours of operation, at least every
6 months
•
Check oil and oil level
•
Check running noise for possible bearing
damage
•
Visual inspection of the seals for leakage
•
For gear units with a torque arm: Check and
replace the rubber buffers, if necessary
•
Depending on the operating conditions (see illus-
tration below), every 3 years at the latest
•
according to oil temperature
•
Change mineral oil
•
Replace rolling bearing grease (recommen-
dation)
•
Replace oil seal (do not install it in the same
track)
•
Depending on the operating conditions (see illus-
tration below), every 5 years at the latest
•
according to oil temperature
•
Change synthetic oil
•
Replace rolling bearing grease (recommen-
dation)
•
Replace oil seal (do not install it in the same
track)
•
Varying (depending on external factors)
•
Touch up or renew the surface/anticorrosion
coating
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com