5
Electrical installation
Connections
Operating Instructions – MOVITRANS
®
TPM12B Mobile Converter, System Frequency A – 25 kHz
25
Pin assignment X21, X31
Function
Connection for energy supply
Connection type
Han
®
Q 4/2, female
Connection image
1
11
3
12
2
4
PE
No.
Name
Function
1
Pole 1
Pick-up 1 or 2
2
Pole 1
Pick-up 1 or 2
3
Pole 2
Pick-up 1 or 2
4
Pole 2
Pick-up 1 or 2
11
n.c.
Not connected
12
n.c.
Not connected
PE
FE
Equipotential bonding / functional earth
5.4.2
TPM12B036 mobile converter
You can connect 2 or 4 U-shaped THM10C pick-ups, each with 0.8 kW rating, to
TPM12B036 mobile converters. If you connect only 2 THM10C pick-ups to the
TPM12B036 mobile converter, you have to use the terminals X21/X22 or X31/X32.
X21
X22
X31
X32
TPM12B036
THM10C
THM10C
THM10C
THM10C
1362541835