30
Manual – MOVIFIT® SNI Fieldbus Gateway UFF41B for MOVIGEAR® SNI
5
SNI gateway configuration
Startup
Configuring
drives
The "SNI gateway settings" window opens. The upper part of the window displays the
parameters for each of the up to 6 MOVIFIT
®
SNI.
In the lower part of the window, you can set the drive parameters and functions of lower-
level MOVIGEAR
®
SNI.
65603ADE
[1]
[MOVIFIT
®
SNI enable] button
To enable MOVIFIT
®
SNI (tab SNI 1 - SNI 6)
[2]
"IP address" edit box
Check/enter the correct IP address of MOVIFIT
®
SNI
[3]
"Cycle time" edit box
Check/enter the correct cycle time between fieldbus
gateway and MOVIFIT
®
SNI (at least 5 ms per
master)
[4]
"PD start address" edit box
Check/enter the correct PD start address. PD start
address for the first MOVIFIT
®
SNI: 2.
[5]
"Local DO/DI" check box
To activate the local binary outputs and inputs
(DO/DI).
[6]
[Ramps] button
To set the ramp times for MOVIGEAR
®
SNI (see the
section "Setting ramp times")
[7]
[Fixed speeds] button
To set fixed speeds for MOVIGEAR
®
SNI (see the
section "Setting fixed speeds")
[8]
[Error response] button
To activate the error response of MOVIGEAR
®
SNI
(see the section "Setting the error response")
[9]
"Enabled" check box
To enable the set MOVIGEAR
®
function
[10] "MOVIGEAR
®
function" dropdown
menu
To set the required MOVIGEAR
®
function (see the
chapter "Description of functions").
[1]
[2] [3] [4] [5]
[6]
[8]
[7]
[10]
[9]
0
0
I
Содержание MOVIFIT SNI UFF41B
Страница 2: ...SEW EURODRIVE Driving the world...
Страница 41: ......