SEW-Eurodrive MOVIFIT SNI UFF41B Скачать руководство пользователя страница 1

Drive Technology \ Drive Automation \ System Integration \ Services

Manual

 

MOVIFIT

® 

SNI

Fieldbus Gateway UFF41B for MOVIGEAR

®

 SNI

Edition 05/2009

16810414 / EN

Содержание MOVIFIT SNI UFF41B

Страница 1: ...Drive Technology Drive Automation System Integration Services Manual MOVIFIT SNI Fieldbus Gateway UFF41B for MOVIGEAR SNI Edition 05 2009 16810414 EN...

Страница 2: ...SEW EURODRIVE Driving the world...

Страница 3: ...2 Required devices 7 3 3 Project planning information 7 3 4 Addressing 7 3 4 1 Important notes 7 3 4 2 Addressing options of the UFF41B fieldbus gateway 8 3 4 3 MOVIFIT SNI via Address Editor 16 3 5 D...

Страница 4: ...r about any of the information in this documentation or if you require further information contact SEW EURODRIVE 1 2 Structure of the safety notes The safety notes in this manual are structured as fol...

Страница 5: ...ou must comply with the information in the manual and the documentation of the units connected to the fieldbus gateway to ensure safe operation and to achieve the specified product characteristics and...

Страница 6: ...onfiguration and parameter setting is carried out using a plug in in MOVITOOLS MotionStudio 65997XX 1 UFF41B fieldbus gateway with SD card OMG42B 2 Ethernet connection between UFF41B X37 fieldbus gate...

Страница 7: ...ected process data profile 1 2 or 3 PD per drive 1 or 2 PD per MOVIFIT SNI you can control up to 6 MOVIFIT SNI in conjunction with 57 MOVIGEAR SNI drive systems via fieldbus gateway The various profil...

Страница 8: ...ed with the PC 1 using a USB connection cable 2 It also shows how the fieldbus gateway 3 is connected with the lower level unit 5 Do the following to connect the UFx41B fieldbus gateway with the PC an...

Страница 9: ...Your PC will detect the new hardware and launch the hardware wizard 2 Follow the instructions of the hardware wizard 3 Click on Browse and go to the MOVITOOLS MotionStudio installation folder 4 Enter...

Страница 10: ...plugs window 2 From the selection field 1 choose the communication type USB In the example USB is activated as the communication type for the first communication channel 2 3 Press the Edit button 3 on...

Страница 11: ...ecessary When doing so refer to the detailed description of the communication parameters USB communica tion parameters The following table describes the communication parameters for the USB communica...

Страница 12: ...Start Settings Network and Dial up Connections select the required PC interface 2 Select Properties from the context menu 3 Activate the Internet protocol TCP IP check box 4 Click on the Properties b...

Страница 13: ...communication type for the first communication channel 2 3 Press the Edit button 3 in the right part of the window This displays the settings for the Ethernet communication type 4 Set up the SMLP prot...

Страница 14: ...t IP address IP address of the local network segment within which the unit scan is carried out In the default setting the unit scan only detects units that are in the local network segment IP address...

Страница 15: ...the Ethernet connection X37 The set IP address will be applied in the next boot process 64352AEN S1 switch setting Meaning Top IP parameter IP address 192 168 10 4 Subnet mask 255 255 255 0 Standard g...

Страница 16: ...dress Editor to find Ethernet stations in a network This is especially useful for finding recently added Ethernet stations The Address Editor also helps you to locate the Ethernet interface of the Eth...

Страница 17: ...the required card To do so click the Select network card icon 3 in the toolbar Click the Start network scan icon 1 in the toolbar As a result the current addresses of all Ethernet stations in the conn...

Страница 18: ...munication parameters window of the respective unit 1 to adjust the IP parameters of an Ethernet station to the network The following fields can then be edited IP address of the Ethernet station IP ad...

Страница 19: ...rolling a MOVIGEAR with a user specific speed by means of two process data words You can configure 4 ramp sets by clicking the Ramps button 3 PD drive function The 3 PD drive function allows for contr...

Страница 20: ...DS file SEW_GATEWAY_UFF EDS INFORMATION The latest version of the GDS and EDS files are available on the SEW homepage http www sew eurodrive com under the heading Software Gateway 1 PD PO PI Assignmen...

Страница 21: ...13 Bit 14 Bit 15 Optional if local inputs outputs are activated during gateway configuration Word 2 Bits 16 31 Local outputs 4 Bits 16 31 Local inputs 16 MOVIGEAR SNI 1PD fixed speeds PO Assignment P...

Страница 22: ...is active Bit 8 Position bit 1 Bit 8 DI00 bit 5 FALSE Error number bit 5 TRUE Bit 9 Position bit 2 Bit 9 DI01 bit 5 FALSE Error number bit 5 TRUE Bit 10 Position bit 3 Bit 10 DI02 bit 5 FALSE Error n...

Страница 23: ...t 6 Bit 6 Warning Bit 7 Bit 7 Error Bit 8 Start Bit 8 Status bit 7 FALSE Error number bit 7 TRUE Bit 9 Bit 9 Status bit 7 FALSE Error number bit 7 TRUE Bit 10 Bit 10 Status bit 7 FALSE Error number bi...

Страница 24: ...bit 7 FALSE Error number bit 7 TRUE Bit 9 Bit 9 Status bit 7 FALSE Error number bit 7 TRUE Bit 10 Bit 10 Status bit 7 FALSE Error number bit 7 TRUE Bit 11 Bit 10 Status bit 7 FALSE Error number bit 7...

Страница 25: ...guring the PROFIBUS gateway for MOVIFIT SNI To start the plug in click the Start button Next open MOVITOOLS MotionStudio From the Network menu choose the item Communication connections Doing so will o...

Страница 26: ...Under Edit 3 you can set details for the Ethernet connection see figure below Under Network adapter 1 you can select the active network interface Confirm the configuration with OK Scan your network u...

Страница 27: ...I in the entire network of the UFF41B fieldbus gateway should be displayed see figure below You can open the SNI gateway configuration by choosing UFx Gateway Configura tor for MOVIGEAR SNI from the c...

Страница 28: ...anual at hand refer to the chapter System Description 5 2 SNI gateway configuration General information Start MOVITOOLS MotionStudio From the Startup context menu choose SNI gateway configuration The...

Страница 29: ...onfiguration press the Start Up button The following window opens The following startup options are available Upload from device default setting All data can be read when the fieldbus gateway has alre...

Страница 30: ...between fieldbus gateway and MOVIFIT SNI at least 5 ms per master 4 PD start address edit box Check enter the correct PD start address PD start address for the first MOVIFIT SNI 2 5 Local DO DI check...

Страница 31: ...sets To set the ramp sets of MOVIGEAR SNI click the Ramp button The following window opens You can make the following settings using the context menu Copy set ramp sets to the clipboard Paste existin...

Страница 32: ...d Paste existing values from the clipboard Apply set values to all MOVIGEAR SNI Confirm with OK Setting the error response To set the error response of MOVIGEAR SNI click the Error response button The...

Страница 33: ...bus gateway Click Next to download the configuration Example 3 MOVIFIT SNI with a total of 24 MOVIGEAR SNI drives are controlled 20 drives are operated with variable speed The initiators of 4 of these...

Страница 34: ...tion The current configuration is saved as xml file 2 Create documentation option The current configuration is documented and saved as pdf file 3 Data management local check box default setting All co...

Страница 35: ...gnosing the process data in both directions The following figure shows diagnostics of the process input and output data The process input and output data transmitted via fieldbus are displayed on 4 ta...

Страница 36: ...MOVIGEAR SNI 5 Process data monitor with integrated control function Startup The following figure shows the configuration in status mode You can toggle between status and control mode by clicking the...

Страница 37: ...data description Once you return to status mode the fieldbus data will be activated immediately Clicking the Update button 1 or pressing the F10 key lets you transmit the current setting of the proce...

Страница 38: ...in the event of a malfunction You open the diagnostic monitor by clicking the Diagnostics button on the initial screen of the SNI gateway see the following figure for an example The Overview tab prov...

Страница 39: ...39 5 Diagnostics Startup The SNI 1 SNI 6 tab see figure below displays the Settings of the relevant MOVIFIT SNI unit SNI 1 SNI 6 in the upper part of the tab Settings of MOVIGEAR SNI units connected...

Страница 40: ...tice 5 How to use the manual 4 General notes Exclusion of liability 5 Rights to claim under limited warranty 5 Structure of the safety notes 4 H How to use the manual 4 I Installation 25 M MOVIFIT 16...

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ...URODRIVE Driving the world SEW EURODRIVE Driving the world www sew eurodrive com SEW EURODRIVE GmbH Co KG P O Box 3023 D 76642 Bruchsal Germany Phone 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive...

Отзывы: