![SEW-Eurodrive MOVI-SWITCH 1E Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/sew-eurodrive/movi-switch-1e/movi-switch-1e_operating-instructions-manual_1250152042.webp)
9
Service
Motor malfunctions
Operating Instructions – Explosion-Protected MOVI-SWITCH
®
Drives
42
9.2
Motor malfunctions
Fault
Possible cause
Measure
Motor does not start up Supply cable interrupted
Check the connections and (intermediate) ter-
minal points, correct if necessary
Brake does not release
See "Brake malfunctions"
Supply cable fuse has blown
Replace fuse
Motor protection (switch) has
triggered
Check that the motor protection (switch) is set
correctly; current specification is on the name-
plate
Motor protection does not trip
Check motor protection control
Malfunction in control or in the
control process
Observe the switching sequence; correct if
necessary
Motor only starts with
difficulty or does not
start at all
Motor power designed for delta
connection but connected in star
Correct the connection from star to delta; fol-
low the wiring diagram
Motor power designed for star-star
connection but only connected in
star
Correct the connection from star to star-star;
follow the wiring diagram
Voltage or frequency differs con-
siderably from the setpoint, at
least when switching on the motor
Provide better power supply system; reduce
the power supply load;
Check cross section of supply cable, replace
with cable of larger cross section if necessary
Motor does not start in
star connection, only in
delta connection
Star connection does not provide
sufficient torque
If the delta inrush current is not too high (ob-
serve the regulations of the power supplier),
start up directly in delta;
Check the project planning and use a larger
motor or special design if necessary. Contact
SEW-EURODRIVE.
Contact fault on star/delta switch
Check the switch, replace if necessary;
Check the connections
Incorrect direction of
rotation
Motor connected incorrectly
Swap two phases of the motor supply cable
Motor hums and has
high current consump-
tion
Brake does not release
See "Brake malfunctions"
Winding defective
Send motor to specialist workshop for repair
Rotor rubbing
Send motor to specialist workshop for repair
Fuses blow or motor
protection trips immedi-
ately
Short circuit in the motor supply
cable
Eliminate short circuit
Supply cables connected incor-
rectly
Correct the wiring, observe the wiring diagram
Short circuit in the motor
Send motor to specialist workshop for repair
Ground fault on motor
Send motor to specialist workshop for repair
25988670/EN – 04/2020