![SEW-Eurodrive MOVI-SWITCH 1E Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/sew-eurodrive/movi-switch-1e/movi-switch-1e_operating-instructions-manual_1250152011.webp)
3
Safety notes
Transportation/storage
Operating Instructions – Explosion-Protected MOVI-SWITCH
®
Drives
11
3.4.2
Restrictions under the European WEEE Directive 2012/19/EU
You may use options and accessories from SEW-EURODRIVE exclusively in connec-
tion with products from SEW-EURODRIVE.
3.5
Transportation/storage
Inspect the shipment for damage as soon as you receive the delivery. Inform the ship-
ping company immediately about any damage. If the product is damaged, it must not
be assembled, installed or started up.
The lifting eyebolts are designed to carry only the weight of the motor without gear
unit. Tighten installed lifting eyebolts. Mounted gear units have separate suspension
attachments, which must be used according to the gear unit operating instructions
when lifting the gearmotor. Do not mount any additional loads.
The installed lifting eyebolts are in accordance with DIN 580. Observe the loads and
regulations specified there. The tension force vector of the slings must not exceed a
45° angle in accordance with DIN 580.
If necessary, use suitable, sufficiently dimensioned handling equipment.
Observe the following notes when transporting the device:
•
Always use all attachment points if available. The attachment points are designed
to carry only the mass of the product. Severe or fatal injuries. Do not apply any ad-
ditional loads.
•
Ensure that the product is not subject to mechanical impact.
If the product is not immediately installed, it must be stored in a dry and dust-free loca-
tion. The product can be stored for up to 9 months without requiring any special mea-
sures before startup. Do not store the product outdoors.
Do not transport or store the product on the fan guard.
3.6
Electrical installation
Ensure that all of the required covers are correctly attached after carrying out the elec-
trical installation.
Make sure that preventive measures and protection devices comply with the applica-
ble regulations (e.g. EN 60204-1 or EN 61800-5-1).
3.6.1
Required preventive measure
Make sure that the product is correctly attached to the ground connection.
3.6.2
Stationary application
Necessary preventive measure for the product is:
Type of energy transfer
Preventive measure
Direct power supply
•
Ground connection
25988670/EN – 04/2020