DHF21B/41B option
Technical Data and Dimension Drawings
7.3
DHF21B/41B option
INFORMATION
Connections identical with those of the DHE21B/41B option are described in the
"DHE21B/41B option" chapter.
DHF21B/41B option
Part number
•
DHF21B: 1823 608 1
•
DHF41B: 1821 161 5
Electrical supply
Installed in MOVIDRIVE
®
MDX61B:
•
Power consumption: P
max
= 8 W
Installed in the MOVIAXIS
®
master module (MXM):
•
Power consumption: P
max
= 10 W
Potential levels
Option DHF21B/41B has the following potential levels:
•
Potential control / CAN 1 / COM1
•
Potential COM2
•
Potential binary inputs and outputs
•
Potential system bus CAN 2
•
Potential PROFIBUS
PROFIBUS connection
X30P:1 – X30P:9
via 9-pin sub D connector, pin assignment to IEC 61158
Bus termination
Not integrated. Activate bus termination with suitable PROFIBUS connector with switchable terminating
resistors.
Automatic baud rate
detection
9.6 kBd – 12 MBd
DeviceNet connection
X30D:1 – X30D:5
•
2-wire bus and 2-wire supply voltage DC 24 V with 5-pole Phoenix terminal
•
Pin assignment according to DeviceNet specification
Baud rate
125, 250 or 500 kBaud, can be set using DIP switches 2
6
and 2
7
Bus cable length
For thick cable according to DeviceNet specification 2.0 appendix B:
•
500 m at 125 kBd
•
250 m at 250 kBd
•
100 m at 500 kBd
MAC ID
0 – 63, can be set using DIP switch 2
0
– 2
5
Max. 64 stations
Engineering
Additional engineering access via the PROFIBUS interface (X30P)
P
i
f
kVA
Hz