
62
Manual – Controllers DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
5
Communication via Ethernet
Project Planning and Startup with MOVITOOLS
®
MotionStudio
8. For the engineering PC, enter an IP address that meets the following conditions:
•
In the blocks that define the
network
, the address segment for the engineering
PC must correspond to the other Ethernet stations.
•
In the blocks that define the
station
, the address segment for the engineering PC
must differ from the other stations.
•
The last block must not contain the values "0", "4", "127" or "255".
NOTE:
In the IP address of the subnet mask (such as 255.255.255.0), the values
in the blocks have the following meaning:
– "255", defines the address of the network where the stations are located.
– "0", defines the address of the actual station to distinguish it from other
stations.
5.5.3
Configuring the communication channel via Ethernet
Do the following to configure a communication channel for Ethernet:
1. Click on "Configure communication connections" [1] in the toolbar.
This opens the "Configure communication connections" window.
2. From the list [1], select "Ethernet" as the communication type.
In the example, "ETHERNET" is activated as the communication type for the first
communication channel [2].
9007200388082827
[1] "Configure communication connections" icon
9007200399122315
[1] "Type of communication" dropdown menu
[2] "Activate" checkbox
[3] [Edit...] button
[1]
[1]
[2]
[3]
0
0
I
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]