With this method, the number of complete pump cycles per minute is 
fixed, within a range of 1 to 6; 4 CPM is the default value which ap-
pears at startup. Each time the up/down arrow keys are pressed, the 
pump refill and discharge times are both automatically adjusted to 
maintain the selected CPM value.  Each adjustment increases or de-
creases the volume pumped per cycle, and the per-minute flow rate is 
the volume per cycle X the CPM value.

OPERATION

8

For example, with a 4 CPM setting, 60 ml volume per cycle equates to 
4 X 60 = 240 ml/min flow rate.  A single press of the Flow up-arrow 
key could change the volume per cycle to 80 ml, for example, resulting 
in a new, increased flow rate of 4 X 80 = 320 ml/min.  And the MP10 
assigns a unique identification value to each setting, the ID value, which 
can be directly set during later sampling events.

"MP" displayed in the lower left corner of the display indicates Micro-
Purge mode.  The default CPM setting of 4 cycles per minute is a good 
starting point for wells with depths from 25-100ft.  MicroPurge mode 
starts at a time setting of 10 seconds refill and 5 seconds discharge, 
close to optimal for many wells.  This startup settings corresponds to a 
4 cycles per minute setting (CPM4) and an ID setting of 103.

Using the CPM key will change the CPM setting on the controller.  The 
range of CPM settings is CPM1 through CPM6.  CPM changes like this 
each time you hit the CPM key: 4  5  6  1  2  3  4  5, etc.  The UP and 
DOWN keys change the flow rate directly, by altering the refill and dis-
charge times 

within

 a CPM setting.  

Note: changes in settings that are 

entered while the controller is cycling are reflected on the next cycle 
change (so a long refill time of 15 seconds will time out before a new 
refill time becomes valid). 

 

Here is an example of the use of the UP (faster) key:

Refill

Discharge

ID

(sec)

(sec)

Key Press

---

1

2

3

10.0

9.5

9.0

8.5

5.0

5.5

6.0

6.5

103

104

105

106

Содержание QED MicroPurge basics MP10

Страница 1: ...1 800 624 2026 FAX 734 995 1170 info qedenv com www qedenv com 1133 Seventh Street Oakland CA 94607 2601 1 800 537 1767 FAX 510 444 6789 QED ENVIRONMENTAL SYSTEMS Ground Water Sampling Remediation Lea...

Страница 2: ...MP10 Controller Optional MP30 Drawdown Meter Well Cap Tubing Air Supply In Pump Air Supply Pump Discharge Well Wizard Bladder Pump R MP10 Basic Setup...

Страница 3: ...the MP10 On Opening Display MicroPurge Mode Using CPM Sampling Use with the MP30 Level Sensing Water Level Meter ID Mode User Time Set MN Mode MP10 Battery Troubleshooting MP10 Specifications QED Serv...

Страница 4: ...ng instructions before operating the MP10 controller Warning Do not disassemble the pneumatic pump while it is connec ted to a compressed gas source Dangerous pressures could cause injury Diagrams and...

Страница 5: ...MN Manual Time Set LVL LevelShutoff CYCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 103 10 0 MP CPM4 05 0 D D E E C...

Страница 6: ...f pump is Refilling or Discharging Cycles per minute setting The mode the controller is in Refill time setting in seconds Time remaining in the cycle ID for time settings Abbreviations CPM MP ID HELD...

Страница 7: ...de water level feedback The MP30 uses a stan dard conductivity probe to detect the ground water surface and a marked tape allowing the user to measure the depth When the meter is set in MicroPurge mod...

Страница 8: ...approximate depth of the sample pump Follow instructions on the battery panel Opening the MP10 case turns power ON Select desired Cycles Per Minute CPM with default value is 4 CPM lower CPM for deeper...

Страница 9: ...red with its lid closed Opening Display The opening display is shown for 5 seconds and displays the controller name the version number and the battery voltage as shown in Figure 1 Figure 1 shows that...

Страница 10: ...ode Figure 2 MP10 MicroPurge Mode Using CPM The MP10 introduces a revolutionary simpler way to con trol bladder pump flow rate and achieve the low flow method used by experts Up down arrow keys are us...

Страница 11: ...ayed in the lower left corner of the display indicates Micro Purge mode The default CPM setting of 4 cycles per minute is a good starting point for wells with depths from 25 100ft MicroPurge mode star...

Страница 12: ...he pump fills and waits Pressing the PAUSE key a second time causes the controller to immediately enter the Sample state Drive air is directed to the pump causing the pump to discharge its volume of l...

Страница 13: ...his allows easy adjustment of the 2 throttle giving pressures that will produce gentle non turbulent flow normally 10 20 Feet H O deeper than pump depth For traditional 2 high volume purging pressure...

Страница 14: ...ler MP Micro Purge ID ID Time Set MN Manual Time Set LVL LevelShutoff CYCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00...

Страница 15: ...ig nals the MP10 to resume pump operation The MP10 resumes by start ing in the refill leg of the pump cycle The normal operating mode for using the MP30 with the MP10 is 1 Use the MP30 in standard WLM...

Страница 16: ...ditional information on the MP30 is given in the MP30 O M manual OPERATION ID Mode Figure 6 shows an example of the MP10 in ID time set mode Once you ve used the MP10 in MP mode and found proper setti...

Страница 17: ...econds will time out before a new refill time becomes valid User Set Mode A final controller mode User Set mode MN on the display is useful for manually setting refill and discharge times on the contr...

Страница 18: ...battery life A fresh set of AA batteries will pro vide more than 100 hours of controller operation at normal operating temperatures As ambient temperatures drop below 15 20F 9C to 6C the ability of th...

Страница 19: ...en in MP mode Temperature below 10F Warm controller Air not cycling through controller Throttle turned too low Turn throttle clock wise to produce pressure Air source not delivering air Verify air sou...

Страница 20: ...s intr oduced from improper battery installation or switch connections LCD display 32 character 2 lines 16 charact ers each Non glare double hardened optical acrylic Sealed NiCd battery pack and 3 use...

Страница 21: ...e defective product with a comparable new unit at no charge to the Buyer or to refund the full purchase price In no event shall such allegedly defective products be returned to QED without its consent...

Страница 22: ...e If the return of a component is determined to be necessary QED will authorize the return of the component at owner s expense If the product proves not be defective within the terms of this warranty...

Страница 23: ...13 5 13 12 5 12 11 5 11 10 5 9 5 9 8 5 8 7 5 7 6 5 6 5 5 5 10 30 31 32 33 34 35 36 37 38 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38...

Отзывы: