background image

 

 

 

About Settop M1 

 

The SETTOP M1-15 is a communication device for remote Total Station monitoring, for use with a

 

 

     

 

 

 

 

 

 

 

 

 

   

Trimble S series Total Station with Finelock. Designed to work independently and autonomously in

   

 

 

 

 

 

   

 

 

 

   

topographic monitoring projects, the SETTOP M1-15 can be connected via Wifi, Bluetooth, Radio,

 

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet, or GSM with SETTOPSurvey’s exclusive IST Connect cloud service. Based on the SETTOP M1

   

 

 

 

 

 

 

 

 

   

 

 

 

receiver, though without the integrated radio and GNSS/GPS technology, the SETTOP M1-15 allows you

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to directly connect various additional sensors and record complete and precise measurements in any

 

 

 

 

 

 

 

 

 

 

 

   

 

project you undertake. Thanks to this unique feature, the SETTOP M1-15 can do much more than a

 

 

 

   

 

 

 

 

 

 

 

 

 

 

   

traditional GPS modem. In addition, its compact design and anodized aluminum casing make the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTOP M1-15 both light and robust, and its IP67 certification for resistance to dust and moisture

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

guarantee its functionality in all weather conditions. 

 

 

SETTOPSURVEY, S.L. Bofarull 14, 08027  Barcelona (Spain)  Phone: (+34) 93 340 05 73  Fax: (+34) 93 351 95 18  

www.settopsurvey.com

  

[email protected] 

 

 

Содержание M1-15

Страница 1: ...User Guide Settop M1 15 4G FW 3 0 0 200527rev 2 ...

Страница 2: ...ack View 10 Upper View 11 Receiver Installation 12 Weather conditions 12 Batteries and Power 12 Powering to Settop M1 12 Powering to other devices 12 Configuring the receiver 13 Default settings 13 Turn on Settop M1 14 Configuring via Wi Fi 14 Configuring via PHONE 14 Configuring the receiver using web interface 16 System Status 17 SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340...

Страница 3: ...p 21 Scheduler 21 Laser 23 Mode 23 Chg Face 23 Turn To 23 Level 24 Tracklight 24 Search 24 Ref Circle 24 Video 25 Webcam 26 COMMUNICATIONS 28 Gateway 28 Modem 28 Wi Fi 29 Bluetooth 30 Ethernet 30 Radio 31 SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 4: ...llation without UPS 43 Basic Installation with UPS 44 Installation with Settop OctoHub and UPS Optic Fiber 45 APPENDIX II FAQ Frequently Asked Questions 46 What to do if the receiver does not turn on 46 The total station is not responding 46 APPENDIX III Accessories and options 47 SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info...

Страница 5: ...ed radio and GNSS GPS technology the SETTOP M1 15 allows you to directly connect various additional sensors and record complete and precise measurements in any project you undertake Thanks to this unique feature the SETTOP M1 15 can do much more than a traditional GPS modem In addition its compact design and anodized aluminum casing make the SETTOP M1 15 both light and robust and its IP67 certific...

Страница 6: ...Enhanced Data Rate wireless technology Communication Ports 1 RS232 Host Event port PPS Power In Out 1 USB OTG port Power In Out 1 TNC connector for GPS antenna 2 FME connector for GSM antenna 1 Slot SIM card 1 Slot MicroSD card Electrical and operating requirements External Power 12 30 V Power All components activated at full power 12 8W Operating temperature 40º a 75º C Storage temperature 55º a ...

Страница 7: ...t store data Constant flashing 1s Storing data Fixed Full memory Power Red LED Status Action Turned Off Not connected Flashing fast and continuous Low battery Fixed Turned on Flashing 1 every 10s Standby Power on unit but unit is turned off SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 8: ... Green LED Status Action Turned Off Doesn t use radio Constant flashing 1 per second Radio signal transmitting e g Mode Base Constant flashing 2 per second Radio signal receiving e g Mode Rover Phone Red LED Status Action Turned Off Doesn t use phone Fixed Doesn t have SIM CARD Constant flashing 1 per second GPRS Coverage Constant flashing 2 per second HSDPA Coverage Constant rapid flashing Error ...

Страница 9: ...linked via bluetooth Constant flashing 3 per second Station connected via cable and bluetooth USB RS232 USB Green LED Status Action Turned Off Device Disconnected Constant flashing 2 per second Device connected via USB in LEMO 2 RS232 Red LED Status Action Turned Off Device disconnected Constant flashing 1 per second Device connected via RS232 in LEMO1 Constant flashing 2 per second Device connect...

Страница 10: ...e Back View Phone GSM Antenna connector COM1 Lemo connector for RS232 power in COM2 Lemo connector for USB power in out Phone GSM Antenna connector Satellites GPS Antenna connector SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 11: ...il the leds are flashing fast 3 Reset password access press the button 3 times when the device is on The next time the Settop M1 WebUI is accessed Shift F5 a dialogue box appears to create a new password SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 12: ...ernal power source is restored the computer will boot automatically with the last settings loaded Autopower option must be enabled ON in the System Settings section The battery supplied with the receiver Settop M1 is a rechargeable Settop Battery II LiFePO4 12 8V 5Ah which allows continuous operation for up to 8 hours Also to ensure continuity of operation it can be connected to the mains transfor...

Страница 13: ... SETTOP M1 default state is Main user Username admin Password No password defined Station not connected Wi Fi configured in ACCESS POINT IP Address 192 168 2 2 IP Ethernet Adapter 192 168 11 98 Subnet MASK 255 255 255 0 Gateway 192 168 11 1 Bluetooth without any link Telephone not configured System Autopower on Bridge Power Limit 15V Language English SETTOPSURVEY S L Bofarull 14 08027 Barcelona Sp...

Страница 14: ...owercase Step 5 Open your Internet browser it supports Google Chrome and Safari and key in IP address 192 168 2 2 Step 6 User name is admin Password The password defined for the first time that access to web or m1 Configuring via PHONE Step 1 Connect Power Cable PN 310655 v3 in COM1 Connect Total Station cable PN 310605 in COM2 Step 2 Press the ON OFF button and wait until the OS Boots Up Phone LE...

Страница 15: ...ors and generators Electric motors Equipment with DC AC converters Fluorescent lights Switching power supplies Low power transmitters such as cell phones and two way radios normally do not interfere with the operation of the receiver It is recommended that you use an uninterruptible power supply UPS to power the receiver A UPS protects equipment from surges and spikes and keeps the receiver operat...

Страница 16: ...status 3 and the project bar 4 1 Main Screen In the central part there is all the space to interact and configure your receiver using the option that allows the device to work When an option is selected all options are displayed in the right sidebar 2 Device Menu Access to the device configuration appears on the left side menu 3 System status At the top a summary of the current system configuratio...

Страница 17: ...tion of the Total Station Communications and System Pressing a second time the menu disappears Data The following icon shows the information of the current system date and UTC time IST Connect The ISTConnect icon refers to the way it is connected and the state it is in connected in green and disconnected in red Pressing on it a menu appears with the basic connection information the Status the User...

Страница 18: ...an be connected by Ethernet cable using the Settop OctoHub accessory by telephone or by Wi Fi In all the options pressing on the icon the basic information associated to the connection appears SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 19: ...Total Station The last icon corresponds to the Total Station TS and indicates the status in which the TS is located The states can be 3 Connected and measuring the angles are shown in Centesimal degrees there is no option to change the units and the measurement method A Autolock FL FineLock LR FineLock Long Range DR Direct Reflex M Manual Waiting for the next round and the remaining time to start ...

Страница 20: ...lso be accessed from Once the status has been modified press Save for the changes to take effect With the service disabled it is an external software that controls the station NOTE It is recommended to have this option activated SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 21: ...d measurement process according to the stored settings During measurement the button becomes STOP Scheduler Scheduler allows the configuration and programming of the rounds according to specific needs Press Save to save the changes By pressing these buttons you can maximize the window minimize the window or close it without saving changes SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34...

Страница 22: ...e continuously without stopping The round interval option disappears It will show a message inform to you that it is not possible to select this option in combination with Trimble T4D 1 2 3 4 5 or 10 Number of rounds to be performed Round Interval It is the waiting time between the beginning of a round and another round it is not the rest time if a time interval is selected that is less than the m...

Страница 23: ...e We can choose between Manual M Autolock A FineLock FL FineLock Long Range LR Direct Reflex DR The preselected mode will prevail when measuring the point Chg Face The Total Station change between Face1 and Face2 Turn To By pressing this button You can select an existing point from the list and turn to it Also You can type or enter the horizontal and vertical angle gon at which you want to rotate ...

Страница 24: ...as this option if not the button is deactivated automatically Search By pressing this button Total Station searches a target automatically You can define the window in HA Horizontal and VA Vertical defined in gon Ref Circle This option allows you to reorient the angles of a total station towards an existing project For example in the case of a Total Station change SETTOPSURVEY S L Bofarull 14 0802...

Страница 25: ...ctive the internal camera and shows the image to control the Total Station By clicking on the lens you can do zoom out zoom in or zoom extension When you press on the camera take a screenshot of the image With the lamp you can adjust the brightness Image size does not fit and can be moved with side arrows SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 ...

Страница 26: ...nect an external webcam and configure it through an IP address a port and a username and password SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 27: ...phone network data transfer is shown at five levels ranging from 0 gray to 100 blue regardless of the technology used In the horizontal top bar you can see the technology used and the coverage level GPRS 2G EDGE 2 5 G UMTS 3G HSDPA 3 5 G LTE 4G Coverage level 0 1 25 26 50 51 75 76 100 SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com ...

Страница 28: ... and connected device has an IP assigned in the range of 192 168 2 xxx All this information appears in the Access Point SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 29: ... pre set and you only need to introduce the password The intensity of the wireless network signal is shown at four levels ranging from 0 white to 100 blue in the horizontal top bar Intensity level 0 25 25 50 50 75 75 100 Bluetooth Not avaiable Ethernet SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 30: ...M Is the option to power other devices connected to COM1 or COM2 from Settop M1 Settop M1 detects automatically if a Settop OctoHub device is connected and it allows new ports Temperature sensor is connected in the COM1 at 9600bps Also it should indicate the maximum power In the event of exceeding this limit the power is cut off This limit can be 10V 15V 20V 25V and 30V Without a Settop OctoHub co...

Страница 31: ... With a Settop OctoHub connected With a Settop OctoHub v2 connected SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 32: ...en the ISTConnect service is active a green indicator appears that is connected Pressing the switch to Disabled will disconnect from the service and the indicator will now be red and will be displayed on the top bar of the system status SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 33: ...sired by pressing Delete The ISTConnect service assigns new communication ports that can be consulted by pressing IST Ports The list shows the service the type of communication as well as the local port and the IST port SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 34: ...rough an IP address You can add different devices by pressing Add as well as delete them Trash button The list of connected devices will appear in the sidebar menu SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 35: ...N default settings the device will automatically turn on when the power supply is connected The button is printed in green By clicking on the Autopower button it asks if we want to disable the functionality When the option Auto power is set to OFF the device does not automatically turn on when the power supply is connected The button is printed in red SETTOPSURVEY S L Bofarull 14 08027 Barcelona S...

Страница 36: ...ssing Update it connects to Settop Upgrade Servers and if there is some new version available it will start to download the latest firmware After downloading the latest version The unit must be rebooted SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 37: ...ement system User may change the password of the administrator of the Settop M1 Reboot Closes all routines turns off the receiver and turns it on again SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 38: ... the name of the reference station and the height of the instrument The Create button is enabled In the case of selecting a project from the list the name and height of the station is displayed The Delete project button is enabled By pressing is possible to download the project file TS By pressing the Upload button a project file can be loaded The supported formats are TS own Settop M1 format and ...

Страница 39: ... the information of the connections made The file with extension GKA also an ASCII file with all the data of the gross observations made It is possible to download the files to the local drive or delete them With the Delete all files button all internal memory is deleted SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsur...

Страница 40: ...and 2 and the possibility of editing them using the pencil button With the selected prism we can change the name the height the constant the type of observation Face1 Face2 and Face1 Face2 and the measurement mode The target can be deleted by pressing Delete or save the changes made by pressing Save We can return to the list by pressing List SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone...

Страница 41: ... being measured and those that remain to be measured Add Measure For adding a new target in the project you need to press Measure Add Target aim to to target and press Measure Fill in all parameters Name Height Constant Face and Measure Mode Finally press Add to project SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurv...

Страница 42: ...es explanatory informative messages may appear at the top of the screen just below the main menu SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 43: ...ations are only in order to get a basic idea of the potential of Settop M1 NOTE The configurations listed below are examples of how to configure the equipment This doesn t mean that this is the only way to configure the system The final configuration is the decision of the user Basic Installation without UPS SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 ...

Страница 44: ...44 Basic Installation with UPS SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 45: ...45 Installation with Settop OctoHub and UPS Optic Fiber SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 46: ...ing The third step is to check the cable connection Make sure the cable is connected properly matching the red dot with the corresponding point of the connector Press the power button to turn on the receiver The total station is not responding The total station that is linked to the M1 doesn t measure or doesn t respond properly In order to get it working correctly you need to reset the Total Stat...

Страница 47: ...Description Image 310662 Settop Octohub v1 310595 Security jail 310596 Base security jail 890305 Pilar platform SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 48: ...on bracket 410159 Monitoring target 46 MP Mini Target TPN 58008040 Trimble Reference target for monitoring SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 49: ...et kit 25 ud 890314 Prism nail 890314 10 Steel nail for prism 890328 Wall clamp TPN 410181 Prism adapter SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 50: ...0mm 60x60mm SETTOP M1 CABINET Customized case PW KIT MON 12V 100Ah Gel Lead Battery SOLAR SYSTEM MON Solar panel 300 Wp 24V SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 51: ...sensor 310605 Cable Settop M1 to Trimble S Series SettopbatteryII External battery Settop II 11 1V 10 4Ah Li Ion SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Страница 52: ... 310512 10 Converter to Fiber UF11 310512 11 Fiber optics cable 2ST 2ST 60200 Antena 4G Mike15 Settop magnetic SETTOPSURVEY S L Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 www settopsurvey com info settopsurvey com ...

Отзывы: