background image

5.0 Returning products for repair

Please contact a Setra application engineer (800-257-3872, 978-263-1400) before returning unit for repair to review information 

relative to your application. Many times only minor field adjustments may be necessary. When returning a product to Setra, 

the material should be carefully packaged and shipped prepaid to:

Setra Systems, Inc.

159 Swanson Road

Boxborough, MA 01719-1304

Attn: Repair Department

To ensure prompt handling, please supply the following information and include it inside the package or returned material:

•  Name and phone number of person to contact.

•  Shipping and billing instructions.

•  Full description of the malfunctions.

•  Identify any hazardous material used with the product.

NOTES:

Please remove any pressure fittings and plumbing that you have installed and enclose any required mating electrical connectors 

and wiring diagrams.

Allow approximately 3 weeks after receipt at Setra for the repair and return of the unit. Non-warranty repairs will not be made 

without customer approval and a purchase order to cover repair chargers.

Calibration Services

 

Setra maintains a complete calibrations facility that is traceable to the National Institute of Standards and Technology 

(NIST). If you would like to recalibrate or recertify your Setra pressure transducers or transmitters, please call our Repair 

Department at 800-257-3872 (978-263-1400) for scheduling.

6.0 Limited warranty & limitation of repair

SETRA warrants its products to be free from defects in materials and workmanship, subject to the following terms and 

conditions:  Without charge, SETRA will repair or replace products found to be defective in materials or workmanship within 

the warranty period; provided that:

a) the product has not been subjected to abuse, neglect, accident, incorrect wiring not our own, improper installation 

or servicing , or use in violation of instructions furnished by SETRA;

b) the product has not been repaired or altered by anyone except SETRA or its authorized service agencies;

c) the serial number or date code has not been removed, defaced, or otherwise changed; and

d) examination discloses, in the judgment of SETRA, the defect in materials or workmanship developed under normal 

installation, use and service; 

e) SETRA is notified in advance of and the product is returned to SETRA transportation prepaid.

Unless otherwise specified in a manual or warranty card, or agreed to in a writing signed by a SETRA officer, SETRA pressure 

and acceleration products shall be warranted for one year from date of sale.

The foregoing warranty is in lieu of all warranties, express, implied or statutory, including but not limited to, any implied warranty 

of merchantability for a particular purpose.

SETRA’s liability for breach of warranty is limited to repair or replacement, or if the goods cannot be repaired or replaced, to 

a refund of the purchase price.

SETRA’s liability for all other breaches is limited to a refund of the purchase price.  In no instance shall SETRA be liable for 

incidental or consequential damages arising from a breach of warranty, or from the use or installation of its products.

No representative or person is authorized to give any warranty other than as set out above or to assume for SETRA any other 

liability in connection with the sale of its products.

For all CE technical questions, contact Setra Systems, USA. EU customers may contact our EU representative Hengstler GmbH, 

Uhlandstr 49, 78554 Aldingen, Germany (Tel: +49-7424-890; Fax: +49-7424-89500). 

Setra Systems, Inc.

159 Swanson Road, Boxborough, MA 01719
800.257.3872  •  www.setra.com

SS-SRIM-EN. E 2/2019

Содержание SRIM1

Страница 1: ...SRIM Operating Instructions Setra Systems Inc 159 Swanson Road Boxborough MA 01719 800 257 3872 www setra com...

Страница 2: ...1 1 Intended use 4 2 0 Mechanical installation 4 3 0 Electrical installation 5 3 1 Plumbing and wiring to the electrical box rough in 6 4 0 Operation 10 5 0 Calibration and adjustment of zero output...

Страница 3: ...for security Audible visual and remote alarms Color backlight LEDs Alarm on pressure temperature and humidity Audible buzzer Alarm delay mute timeout alarm enable disable buzzer enable disable SPDT re...

Страница 4: ...vailable in 4 20 mA 0 5 or 0 10 VDC in the same unit True differential pressure is displayed with a resolution of up to 0001 as well as the room status Setra s patented very low pressure capacitance s...

Страница 5: ...sed to mount to a wall or into a 3 gang off the shelf electrical box Conduit 1 2 or a PG9 cable connection are available for wiring to the terminals at the rear of the unit The rear housing acts much...

Страница 6: ...t from the housing Fig 3 3 Removing bezel from the base Fig 3 4 Rough plumbing and wiring to rough in box flush mount unit 3 1 Plumbing and wiring to the electrical box rough in Flush mounting Use a 3...

Страница 7: ...Fig 3 5 Wiring diagram SRIM1 and back of unit Pull wires through the openings in the bottom of the base 1 2 conduit or PG9 fitting openings are provided Rotating pressure fittings can point up or dow...

Страница 8: ...f NO contact D12 Not used AN1 output of temperature sensor if used A_COM Common output of temperature and humidity sensors if used AN2 output of humidity sensor if used COM 15V power common return 15V...

Страница 9: ...9 Fig 3 7 Wiring SRIM2 Note Relay 1 RLY1 is a SPDT relay that can be used to signal a remote unit of an alarm condition The relay contacts are rated for 3 A 120 VAC...

Страница 10: ...des Be sure to carefully align the 2 parts and push straight in There are alignment features on the front bezel and rear housing 4 0 Menu navigation and configuration The LCD display is standard on al...

Страница 11: ...the indicated differential pressure and units Line 2 indicates the temperature and humidity reading if enabled The green backlight indicates that the room pressure the temperature and humidity is with...

Страница 12: ...lue and flashes twice and to prompt the user that the currently set value has been saved Return Silence button This button provides a quick way to return to the home screen from anywhere within the me...

Страница 13: ...MODE Sets the unit into unidirectional or bi directional pressure modes ex 0 25 or 0 0 25 WC DOOR SWITCHING Only Available on SRIM2 Door switch enable disable Enable if used with a door switch to det...

Страница 14: ...out any 0 pressure error This must be done with 0 pressure applied SPAN CALIBRATION Tares out any Span pressure error This must be done with the Full Range FR pressure applied For ex if the pressure r...

Страница 15: ...select F C T_Min Vin Input the analog output of the temperature sensor corresponding lowest temperature to be measured T_Min T Ex 0 V 50 F T_Min T Input the minimum temperature that corresponds to th...

Страница 16: ...n pressing the enter key will drop down into the setup of the external sensor for AN2 Analog input 2 HUMIDITY ENABLE Pressing the down arrow toggles between enable and disable H_Min H Input the minimu...

Страница 17: ...RM ENABLE Enable or disable the Humidity alarms by using the down arrow to toggle between selections Press Return key to accept selection RETURN Returns from the configuration mode to the normal opera...

Страница 18: ...e menu item PASSWORD ADMIN the system will prompt to input the password when the input is complete press the Enter key to save the password and complete the setup When password protection is enabled y...

Страница 19: ...at calibration was successful Full scale calibration Note The full range adjustment should be completed after zero adjustment Span adjustment should only be performed if a very accurate and stable Ful...

Страница 20: ...y period provided that a the product has not been subjected to abuse neglect accident incorrect wiring not our own improper installation or servicing or use in violation of instructions furnished by S...