Failure to obey the following notices could result in property damage:
● Keep sand or dirt away from the cooling system ventilation area.
● Do not leave the cooler on the deck of a boat for an extended period. Salt water damage to the
cooling system, electronics, or metal hardware could occur.
● Do not expose the cooler to extreme heat.
● Only use mild soap and water to clean the cooler.
● Do not use a DC extension cord.
● Do not use a power strip or two-way splitter.
● Do not use power cord adapters of any kind other than those provided by the manufacturer.
● Do not use ice cubes or
fi
ll the cooler with water. If ice does accumulate at the bottom of the cooler,
defrost the unit and use the drain plug to drain the water.
● Do not modify the unit in any way.
● Do not place hot materials (75 °F or higher) in the cooler. Allow materials to cool (50 °F or less)
before placing them inside the cooler.
● Do not tip or store the cooler at an angle greater than 30° for extended periods. Compressor oil
contamination of the cooling system could occur.
● Allow 2–4 inches of space around the cooler at all times for proper ventilation of the cooling system.
● The cooler must be secured at all times using straps or a mounting plate, especially in mobile
applications.
Number
of
fl
ashes
Error type
E1
E2
E3
E4
E6
Thermal head fault
(
Open circuit or short circuit)
Fan error/Short circuit/ Frequently start and stop(Amp
>
0.65A)
The low battery protection mode take effect (the input voltage is lower than set value)
Compressor motor start error (Motor block or refrigeration system pressure difference is
too large.)
The motor speed of the compressor is too low (the refrigeration system is overloaded,
the motor cannot maintain the minimum speed of 1850r/min)
Temperature too high or too low to protect the compressor control module (when the
environment temperature is too high or too low, or system load is too large, causing
module/ECU internal temperature 100 °C > or < - 10 °C)
>
E5
1
0
.
NOTICE
1
1
.
FAULTS