Sethco ZKX 3/4CS Скачать руководство пользователя страница 4

SAFETY RULES FOR SETHCO VERTICAL PUMP MODEL ZKX

SETHCO

A Met-Pro Fluid Handling Technologies Company

Thermoplastic Pumps

Congratulations: You have just purchased a SETHCO PUMP, a quality industrial product manufactured to exacting standards.

Thank you for choosing a SETHCO product. We look forward to serving your future requirements for quality industrial corrosion 
resistant pumps and filter supplies.

To insure prolonged life of your purchase, please take time to review and understand completely the operating instructions and 
become familiar with the pump before installing, filling, operating or maintaining this equipment.

INSTALLATION – OPERATION – MAINTENANCE

of this equipment must be performed by trained and qualified personnel in strict 

accordance with the operating instructions and all applicable drawings, specifications and codes.

Obtain,  read  and  understand  the  MSDS  (Material  Safety  Data  Sheet)  for  the  liquid  being  handled  before  installing,  filling, 
operating or maintaining this equipment.

Obtain instructions from the Safety Engineer responsible for your facility before installing, filling, operating or maintaining this 
equipment and connected systems.

The equipment as received has been chosen for a certain application or service. 

DO NOT USE

for any other application unless writ-

ten permission is obtained from the SETHCO factory. Consult the SETHCO factory with all of the service requirements so that we
can assist you in a successful reapplication.

Always wear appropriate protective apparel when working on or around the pumping equipment. Gloves, aprons, footwear, faceshield
and/or  breathing  apparatus  and  any  other  protective  gear  as  needed  for  protection  or  as  required  by  facility  or  operating 
procedures.

All unauthorized personnel should be kept a safe distance from any and all work areas.

Keep hands, fingers, or tools from contacting the impeller during operation of the pump and system. Disconnect, lock and tag out
the main power source to prevent accidental start up.

Always keep face away from openings in the pump equipment. 

DO NOT

look into hose, pump discharge or suction connections.

All auxiliary equipment such as hoses must be suitable for the chemical to be transferred. They must also be selected to safely 
contain the system pressure at the operating temperature. All hose clamps must be of a material that will not be attacked by 
corrosive environment or splashing of pumped liquid.

All connections should be checked for a secure liquid tight fit prior to filling and/or operating pump equipment or system.

Never turn pump on unless discharge and suction valves are open.

When connecting or wiring motor, follow all applicable electrical and safety codes.

Protect the power cable (when applicable) from sharp objects. 

DO NOT

crimp or bind the power cable and never allow the cable to

come in contact with water, oil, grease, hot surfaces, or chemicals.

Disconnect, lock and tag out the main power source to the motor before handling the pump/motor for any reason. Lock and tag out
the switching device to prevent the unexpected application of power. 

FAILURE COULD RESULT IN SEVERE INJURY OR DEATH

.

Avoid touching the exterior surface of the motor. It may be hot enough to be painful or cause injury.

Isolate  the  pump  by  closing  suction  and  discharge  valves  prior  to  any  maintenance.  Lock  and  tag  out  the  valves  to  prevent 
accidental opening.

Do not attempt to perform any maintenance on the pump/motor unit until you are confident that the pump and its contents have been 
neutralized and stabilized at ambient temperature and atmospheric pressure. 

FAILURE COULD RESULT IN SEVERE INJURY 

OR DEATH

.

Sethco

800 Emlen Way, Telford, PA 18969

Tel: 

215-799-2577 •

Fax:

215-799-0920

w

ww

ww

w..s

se

etth

hc

co

o..c

co

om

m •• iin

nffo

o@

@s

se

etth

hc

co

o..c

co

om

m

3

Содержание ZKX 3/4CS

Страница 1: ...l 215 799 2577 Fax 215 799 0920 w ww ww w s se et th hc co o c co om m i in nf fo o s se et th hc co o c co om m O O O OP P P PE E E ER R R RA A A AT T T TI I I IN N N NG G G G I I I IN N N NS S S ST...

Страница 2: ...t th hc co o W Wa ar rr ra an nt ty y 2 S Sa af fe et ty y R Ru ul le es s 3 O Op pe er ra at ti in ng g I In ns st tr ru uc ct ti io on ns s 4 General Description 4 Pre installation 4 Pump Installati...

Страница 3: ...atory tests with cold water as outlined in the Hydraulic Institute Standards Due to the inaccuracies of field testing the results of any such tests conducted by or for the Buyer shall be interpreted a...

Страница 4: ...rom any and all work areas Keep hands fingers or tools from contacting the impeller during operation of the pump and system Disconnect lock and tag out the main power source to prevent accidental star...

Страница 5: ...pump shaft must be vertical to avoid damage during operation PIPINGTHE PUMP The pump has been designed with all necessary strength factors for a long reliable service life However due to thermoplastic...

Страница 6: ...ry Periodically check pressure and flow rates Adjust if necessary DISASSEMBLY Ensure that the motor is shut off then lock and tag out power supply Check that the discharge valve is shut and any liquid...

Страница 7: ...letely plugged Wrong direction of rotation Air leak in the suction line Discharge valve closed INSUFFICIENT DISCHARGE Air leaks in suction Speed too low System head higher than anticipated Insufficien...

Страница 8: ...Pump mount is level and plumb Mounting bolts are tight Motor mounting bolts tight Suction and discharge connections secure Electrical connections secure and covered Turn motor fan by hand ensure that...

Страница 9: ...ZKX 3 4CS ASSEMBLY DRAWING 8...

Страница 10: ...ZKX 3 4CS OUTLINE DRAWING 9...

Страница 11: ...ZKX 3 4CS CURVES 3500 RPM 10 3500 RPM 3500 RPM...

Страница 12: ...ZKX 3 4CS WIRING DIAGRAMS 11...

Страница 13: ...12 NOTES...

Страница 14: ...ED TRADEMARK OF MET PRO CORPORATION OM 354 05 PVDF409 800 Emlen Way Telford PA 18969 Tel 215 799 2577 Fax 215 799 0920 w ww ww w s se et th hc co o c co om m i in nf fo o s se et th hc co o c co om m...

Отзывы: