OPERATION 

 
 

Safety 

Correct installation is the most critical factor in ensuring the safe use of 
the power supply. If every consideration in the 

Installation

 section of this 

manual has been satisfied the power supply will be safe to operate. 
 

Operating Modes 

The BCE4 and BCE5 have three main operating modes: 

 

• 

As a battery eliminator it may be used to power equipment requiring  
12V –14V at 10Amps. (24 –28V at 5Amps for BCE5). It is fully 
protected against overload and short circuit as well as incorporating 
over voltage protection. 

 

• 

As a lead acid battery charger it will provide safe and convenient 
method to restore discharged batteries.  Fully charged batteries can 
be left connected to the unit indefinitely with no adverse effects on 
their lifetime.  

 

• 

The full features of the unit are realised when both a battery and a 
load are connected so that it operates as a power supply with power 
fail protection. Under normal conditions an internal switch connects 
the battery in parallel with the load. The average load must be less 
than the capability of the power supply to ensure there is a remainder 
available to float charge the battery. 
 
When a mains failure occurs, the power supply no longer provides 
power. The battery now supports the load without interruption of the 
load. Restoration of the mains restarts the power supply which will 
resume support of the load and charging of the battery. 
 
During extended mains failures the unit disconnects the battery 
before it becomes excessively discharged. The battery is 
automatically reconnected when the mains recovers. This feature 
contributes to long battery lifetime and allows unattended operation of 
a system.  

 

Protection 

The power supply incorporates the following protection features 
 

• 

Reverse polarity connection of the battery will not cause damage to 
the power supply or the battery and the output load will remain 
unaffected.  

• 

Battery fusing is provided in series with battery connection to protect 
the load and power supply when it is powered from the battery. 

Issue D 

 

Page 5 of 13

 

Содержание BCE4

Страница 1: ...SETEC MODEL BCE4 BCE5 USER S MANUAL Document No 010812 Issue D Page 1 of 13...

Страница 2: ...ALIA Phone 61 3 9763 0962 Fax 61 3 9763 8789 Email sales setec com au WARNING This product Contains Hazardous voltages which can cause death It should only be serviced by properly qualified personnel...

Страница 3: ...Protection 5 Battery LVD Operation 6 Indicators 6 Alarm 6 Output Voltage Adjustment 6 SPECIFICATION 8 MECHANICAL 9 MOUNTING 10 INSTALLATION 11 Personnel 11 Mounting Options 11 Connectors 11 Hooking Up...

Страница 4: ...the output Many other applications will be able to take advantage of these features Features include Light compact design High Efficiency Battery over discharge protection with automatic reset High re...

Страница 5: ...onditions an internal switch connects the battery in parallel with the load The average load must be less than the capability of the power supply to ensure there is a remainder available to float char...

Страница 6: ...ion incorporated against a reversed battery connection A reversed battery is left disconnected so that the LOAD output can still run the load from mains power The quiescent current drain on the batter...

Страница 7: ...the output connector with the battery disconnected Failure to disconnect the battery can result in incorrect output voltage setting and over charging of the battery may result The output voltage is fa...

Страница 8: ...Battery Reconnect 11 9 0 3V 20 5 0 6V Battery Hysteresis 1 7V typ 3 0V typ Battery Fuse 15A 32Vdc 10A 32Vdc Load Regulation 1 2 from set point taking into account all of line and load regulation and t...

Страница 9: ...ICAL 111 0 224 0 59 0 Figure 1 Overall Dimensions 63 0 186 5 15 3 81 6 47 8 13 0 5 5 10 0 Figure 2 Mounting Points Turn clockwise to increase output voltage Figure 3 Voltage Adjustment Issue D Page 9...

Страница 10: ...assis is 4mm M3 Screw Front Panel Figure 3 Front Panel Mounting Rubber Feet Flat Washer M3 x 8mm Screw Figure 5 Bench Mounting M3 Screw Maximum protrusion of M3 screw into chassis is 4mm Mounting Pane...

Страница 11: ...so it is important that the screw lengths are adhered to Connectors Input Mains IEC320 DC Output 6 Way female plugable type Pinout for the DC output connector is as follows Pin Function 1 0V 2 0V 3 Lo...

Страница 12: ...ng alarm relay contacts Connect these pins to any circuit which is required to be activated by an alarm condition The 2 pins become shorted when an alarm condition occurs These pins must not be connec...

Страница 13: ...mounting 60mm min 60mm min 20mm min Note The maximum ambient operating temperature of the power supply is defined as the temperature of the air entering the bottom of the power supply This may not be...

Отзывы: