9 of 10
SET-1240
Technical Description
Issue
02
13/04/2022
LED Behavior
LED Name
LED Behavior
Definition of Behavior
PWR
Off
No power present on the board
Solid green
Power good state
RDY
Off
Module card is unpowered or reset active
Solid green
Card is recognized by chassis and ready to communicate
Amber
Chassis is communicating
Error Handling
LED Name
LED Behavior
Actions
PWR
Off
-
Check power supply of chassis
-
Check external power supply if used
PWR
Blinking Red
-
Check plugin module on board
-
Check fuse on board
Hardware Specifications
Absolute Maximum Ratings
Property
Condition
Value
Comment
Max. Excitation Voltage
Recommended
Operation Range
400
Hz ≤ f
Exc
≤ 1
kHz: 3 V
RMS
1 kHz < f
Exc
≤ 10
kHz: 7 V
RMS
Operation without
damage
10 V
RMS
Max. Common mode
Excitation Voltage
45 VDC
Min. Common mode
Excitation Voltage
-45 VDC
Max. RTI CNTL Voltage
+10 V
Min. RTI CNTL Voltage
-10 V
Excitation Frequency
Recommended
Operation Range
400 Hz
–
10 kHz