6. Menu / Operation
32
6.3.6 Operating mask
Displayed in normal operation mode.
Displayed information:
Current product name (top right)
Se:
Sensitivity (0 - 100%)
PA:
Product angle (0° - 180°)
Info field:
Current time, status of outputs etc
….
Signal:
Current signal of the metal detector
Signal value >100
Metal signal
Different displays:
The Control Unit needs approx. 5 sec. for the start-up process.
If the outputs are disabled via menu settings, the display will illustrate this by
showing
Output OFF
In addition, the green operating/fault light is off and a log entry is created.
If metal detection is deactivated over the digital bypass, the display shows
ByPass
The Operation/Fault LED goes off (not operating), and an entry is made in
the logbook.
This display appears in case of an error message. The Operation/Fault LED
flashes red, and a corresponding entry is made in the logbook.
This example shows an error from air pressure monitoring.
When the cause of the error has been remedied, the error message can be
reset by pressing the hardware RESET key.
Warning messages have no influence on the operation of the system.
Warning in case of
- Battery power too low or battery missing.
The Operation / Fault LED flashes green.
On detection of metal, the mask on the left is displayed, the red metal light
comes on and a log entry is created.