5. Commissioning
20
5.2.4 Electrical performance
Potential-free relay contacts
250V 3A with alternating voltage
120V 3A with direct voltage
For the potential-free relay circuits fusing must be provided outside the equipment.
Switching outputs (MV1, MV2, MV3)
Switching outputs (LM, LB, LF, Mz)
Maximum current load: 250 mA
Maximum current load: 150 mA
Switching inputs
Connection of make contacts 24 V,
connection of sensors (PNP, NPN)
total max. permissible current load 24V / 150 mA
5.2.5 Drawing of input / output connections
Switching outputs
J5
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
NC
Not
used
LM
Light
metal
LB
Light
oper-
ating
LF
Light
error
1
2
3
MZ
Metal
counter
MV1 MV2
MV3
Switching inputs
J6
Sensor1
25
26
27
28
29
30
31
32
Sensor2
17
18
19
20
21
22
23
24
P
Pressure
switches
External
test
External
Reset
Manual
separation
Disable
metal
detection
At J5, J6 only circuits that are isolated from the mains supply by way of double insulation
(SELV circuits) may be connected.