appropriate  collection  site  in  accordance  with 
government regulations.  

Japan: 

Recycling  of  expended  lithium-ion  battery  packs  is 
regulated  by  the  Wastes  Disposal  and  Public  Cleaning 
Law and the Law for Promotion of Effective Utilization.  

Brazil:

 

Expended  battery  packs  should  be  recycled  in 
accordance to the Natation Solid Waste Policy (PNRS) or 
CONAMA  in  compliance  with  the  directives  and 
regulations  of  the  National  System  of  Environmental 
(SISNAMA). 

Malaysia: 

Lithium-ion cells and batteries are considered scheduled 
wastes  and  must  be  sent  to  a  proper  collection 
treatment,  recycling  and  Disposal  Centre;  Scheduled 
Waste Code SW103. 

Classification  of  Waste  to  comply  with  Transport  Regulations: 
Expended  Lithium-Ion  Battery  packs  are  not  considered  hazardous 
waste.  Lithium-ion  battery  packs  that  have  been  involved  in  a  fire 
maybe  considered  hazardous  waste  and  should  be  marked  and 
classified as such.  

Classification  of  Waste  Packaging  Material:  Under  normal  use 
packaging  is  not  consider  hazardous  and  should  be  disposed  of  in 
accordance with local recycling regulations. Packaging that has been 
exposed to a damaged leaking cell should be considered hazardous 
waste and disposed of in accordance to local rules and regulations. 

 

 

 

 

3  REQUIREMENTS 

 
3.1 

General Requirements  

 

3.1.1.  Nominal Voltage 

 

The battery nominal operating voltage is 14.4V 

 

3.1.2.  Rated Capacity 

 

The  initial  capacity  is  5700mAh  (based  on  a  CV  charge  of 

16.8V±50mV  with  a  current  limit  of  2900mA  and  6000mA 
discharge to 11.4V @ 25C, within 1 hour of charge). 
 

 

3.1.3.  Initial Impedance 

 

The  internal  impedance  of  a  fully  charged  battery  shall  be 

≤207

m

  when  measured  across  the  positive  and  negative 

battery terminals at 1kHz at 20°C. 

 
 

Содержание SE-2030

Страница 1: ...ery Model SE 2030 SE20300NR29 14 4V 5 7AH 82 08Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...9Ah giving a battery pack of 14 4V and 5 7Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMBus and SBDS Revisi...

Страница 4: ...ffected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove the battery from the equipment wh...

Страница 5: ...ult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken open consult hazardous waste regulations under US Envir...

Страница 6: ...ks are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be marked and classified as such Classification of Waste P...

Страница 7: ...w 80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notif...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...pack for mechanical alignment adjacent to the positive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 10K pull up resist...

Страница 10: ...n pack LED s with push button activation Charge control is used to provide optimal and safe charging requests to an SMBus level II or level III charger The system has three modes of operation normal s...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...te Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a command to the sl...

Страница 14: ...t Battery Slave 3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2030 Device Chemistry 0x22 Returns a...

Страница 18: ...threshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Dis...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Страница 21: ...ing Connector The recommended interconnection mating male connector is AMP TE part no 6123738 7 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specif...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 16 8 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: