SES SE-2030 Скачать руководство пользователя страница 15

 

 
 

SEALED ENERGY SYSTEMS

®

 

15 

User Manual  

      

 

Battery Broadcast Message for the Charger 

 

 

Battery Broadcast Message for the Charger w/PEC

 

 

 
 

  SMBus Host (Master)                    Smart Battery (Slave) 

 
 

 

 

3.3.6.  SMBus battery Critical Message Protocol  

 
A  Smart  Battery  to  SMBus  Host  or  Smart  Charger  message  is  sent 
using  the  SMBus  Write  Word  protocol.  Communication  begins  with 
the SMBus Host’s or Smart Battery Charger’s address, followed by the 
Smart  Battery’s  address  which  replaces  the  Command  Code.  The 
SMBus  Host  or  Smart  Charger  can  now  determine  that  the  Smart 
Battery was the originator of the message and that the following 16 
bits are its status. 

 

Battery Critical Message  

 

Battery Critical Message w/PEC

 

 

 
 

  SMBus Host (Master)                    Smart Battery (Slave) 

 

 

 

 
 

3.3.7.  Host to battery Message (Slave Mode)  

 
The Host acting in the role of bus master uses the read word, write 
word,  and  read  block  protocols  to  communicate  with  the  battery, 
operating in slave mode. 
 
 

 

1  1 

Charger 
Address 

Wr  A 

Command 

Code 

Data Byte 

low 

Data Byte 

High 

A  P 

1  1 

Charger 
Address 

Wr  A 

Command 

Code 

Data 

Byte 

low  

Data 

Byte 
high  

PEC 

A  P 

1  1 

Target 

Address 

Wr  A 

Battery 

Address 

Data Byte 

low 

Data Byte 

High 

A  P 

1  1 

Target 

Address 

Wr  A 

Battery 

Address 

Data 

Byte 

low 

Data 

Byte 

High 

A  PEC  A  P 

Содержание SE-2030

Страница 1: ...ery Model SE 2030 SE20300NR29 14 4V 5 7AH 82 08Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Страница 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Страница 3: ...9Ah giving a battery pack of 14 4V and 5 7Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMBus and SBDS Revisi...

Страница 4: ...ffected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove the battery from the equipment wh...

Страница 5: ...ult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken open consult hazardous waste regulations under US Envir...

Страница 6: ...ks are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be marked and classified as such Classification of Waste P...

Страница 7: ...w 80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notif...

Страница 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Страница 9: ...pack for mechanical alignment adjacent to the positive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 10K pull up resist...

Страница 10: ...n pack LED s with push button activation Charge control is used to provide optimal and safe charging requests to an SMBus level II or level III charger The system has three modes of operation normal s...

Страница 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Страница 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Страница 13: ...te Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a command to the sl...

Страница 14: ...t Battery Slave 3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus...

Страница 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Страница 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Страница 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2030 Device Chemistry 0x22 Returns a...

Страница 18: ...threshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Dis...

Страница 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Страница 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Страница 21: ...ing Connector The recommended interconnection mating male connector is AMP TE part no 6123738 7 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specif...

Страница 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 16 8 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Страница 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Страница 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Отзывы: