5
PLIOMARK PRINT EOS5
2. Installation of the printer, the product to be printed and the ribbon.
1. The printer is equipped with a label detection sensor. If the product to be printed has a recurring perforation,
place the sensor over the perforation. This can be placed in different places depending on the product to be prin-
ted.
2. To adjust the position of the sensor in front of the hole, press the side pin. Turn the pin to position the sensor.
Once the adjustment is made, it is important to return the side pin to its initial position so that the print head can
be locked properly.
3. If you are using products to be printed without perforation, place the sensor directly on the product to be printed.
The sensor will detect the gap between the labels.
✽