![Servotronix CDHD Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/servotronix/cdhd-series/cdhd-series_application-note_1247111009.webp)
Pulse and Direction Using Single-Ended Signal
Wiring
Application Note
9
2
Wiring
The Pulse signal is connected to CDHD fast digital input 5 – Controller I/F C2
pin 32.
The Direction signal is connected to CDHD fast digital input 6 – Controller I/F C2
pin 15.
Fast Digital Inputs Specifications
Signal
Configurable Opto-Isolated
(compatible with sinking output)
Voltage
24 V
Max Input Current
10 mA
Propagation Delay Time 1 µs
The following diagram shows how to connect the PLC to the CDHD Controller IF
(C2) connector.
Connect the cable shield on the PLC side to any available shield connector.
Connect the cable shield on the CDHD side to the shell of the 36-pin
connector.
Note
: The 24 VDC power supply must be provided by the user.
Содержание CDHD Series