Menu Control
Control type [PushB 1...5]
(on page 2v2)
Typical use: 2 step switching like gear
change on the Servonaut M24 speed
controller.
This control type has five positions like the
type [Seq 1…5] but the rest position is in
the center. By pressing the button the
control will switch to the end position in two
steps. The time between the steps can be
adjusted in the menu. If the time is set to
“0” the control will instantly switch to the
end position.
Control and servo channel assign-
ment (mixer function)
Each control can affect up to four servo
channels - one servo channel can be
affected by any number of controls.
Caution:
You need to assign at least
one servo channel to a control other-
wise it has no function! If you have selected
the model template MC19 the joysticks are
assigned to the servo channels 1 to 4 as
usual with Graupner.
Caution:
Don’t assign the same
servo channel to one control more
than once. Errors may occur!
With the model template FC14 the joysticks
are assigned to the servo channels 1 to 4 as
usual with Robbe/Futaba. But basically you
can choose the assignment as you like.
Make the assignment in the control menu on
page 2 to 5 by selecting the servo channel.
Press [Reset] to delete the assignment.
See
chapter Mixer Functions for examples
Control type [Impulse]
(on page 2v2)
Typical use:
Control light sets
See chapter
Light Sets
Caution
: With some light sets e.g. the
ML4
short
and
long
key
strokes/joystick moves cause different func-
tions. To assign these functions to different
softkey pairs your HS16 has the control type
[Impuls].
•
Joysticks: Not useful
•
Softkey pair: Same as control type
[Normal] but the values -100% or +100%
are set for an adjustable time - no matter
if the key is pressed shortly or long.
Control type [Min Impulse]
(on page 2v2)
Works like control type Impulse. But by
holding the control you can expand the
impulse as long as you like. The set impulse
length is therefore the minimum impulse
length.
Control type [Seq 1...5]
(on page 2v2)
A control with five positions. Each of the
positions are set like with channel type “5
Pos Servo”. This control moves automati-
cally from the left to right (or right to left) stop
within a set time. If the time is set to 0 you
can switch to the five positions manually. In
combination with the channel type [5 Pos
Servo] you get a simple sequence control.