USE RESTRICTION 

The information contained in this chapter  provides important prescriptions for operating safely during all 
phases of the product's life. 
Not  knowing  or  not  complying  with  these  provisions  can  generate  dangerous  situations  that  could  cause 
damage to equipment and risks for the safety of persons. 

4.1

 

Intended use 

Actuators are used to perform very different functions within machines. It is the responsibility of the machine 
builder to design the application in compliance with the laws in force in the specific sector and in the field of 
safety, in compliance with the requirements provided in the product catalog and in this manual. 

 

ACTUATORS ARE ELECTRIC AXIS, WHATEVER DRIVER OR CONTROL WILL BE USED: THE SELECTION OF 
THE PRODUCT AS STROKE, SPEED, TYPE OF LIMIT SWITCHES, MOTOR AND BRAKE, MUST BE DONE 
ACCORDING TO THE BEHAVIOR EXPECTED, IN FUNCTION OF THE TYPE OF CONTROL CHOOSEN AND 
THE STATIC AND DYNAMIC BEHAVIOR OF THE SYSTEM IN WHICH THE ACTUATOR IS PLACED! 

The  actuators  have  been  designed  and  built  to  operate  mobile  parts  of  various  types,  shapes  and 
construction, in the ways and within the limits set out in the descriptions and tables of the technical data in 
the catalog and in this user manual. 
The actuators are designed to work with a purely axial applied load. 
They must be subjected to the loading and speed conditions specified in the catalog. 
Modification of parts of the actuator or replacement of components with different and non-original parts is 
not permitted. The replacement of components with original spare parts is carried out only by Servomech 
S.p.A. 
Any different  use  is to be considered improper and therefore  potentially dangerous for the safety of the 
operators, as well as such as to void the contractual guarantee. 
In the event of particular processing requirements, we recommend consulting our sales department. 
Every modification must be authorized by Servomech S.p.A. with written documents. 

 

ANY OTHER USE OUTSIDE THAT THAT JUST DESCRIBED IS NOT PERMITTED BY SERVOMECH S.p.A. 

4.1.1

 

Use restrictions 

Actuators can not be used for unforeseen applications. 

Any utilization of this device beyond its intended purpose may lead to potentially hazardous situations. 

Therefore: 

 

Strictly adhere to all safety precautions and instructions in this operating manual. 

 

Do not allow this device to be subjected to weather conditions, strong UV rays, corrosive or explosive 
air media as well as other aggressive media (*). 

 

Do not modify, retool or change the structural design or individual components of the actuator. 

 

Never use the device outside of the technical application and operational limits.

 

 
(*) – THE USE OF THE ACTUATOR IN ABOVE CONDITIONS MUST BE PREVIOUSLY DECLARED AND AGREED 
WITH SERVOMECH, SINCE A SPECIAL EQUIPMENT OF THE PRODUCT MUST BE PROVIDED.   
 
 

 

Содержание ATL 20

Страница 1: ...TL 28 ATL 30 ATL 40 BSA 20 BSA 25 BSA 28 BSA 30 BSA 40 Installation operation and maintenance manual Publication 02 20 25 28 30 40 E Rev 01 Date M Y 05 19 Servomech S p A Via M Calari 1 40011 Anzola d...

Страница 2: ...y relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not r...

Страница 3: ...tions 7 4 1 2 Standard operating conditions 8 4 1 3 Thermal limit 8 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 9 6 1 Safety warnings 9 6 2 FCE electric stroke limit switche...

Страница 4: ...BO ITALY Ph 39 051 6501 711 Fax 39 051 7345 74 Website www servomech com e mail info servomech com 2 2 Description of the product For all the technical characteristics of the product performance featu...

Страница 5: ...o of the input drive 3 Stroke length is the stroke length in millimetres achievable by the actuator 4 Linear speed is the linear speed expressed in mm s when the actuator is provided with electric mot...

Страница 6: ...g and transporting the linear actuator the push rod must be in retracted position Lift the actuator from the housing and outer tube supporting the motor during transport DO NOT lift the actuator from...

Страница 7: ...ith a purely axial applied load They must be subjected to the loading and speed conditions specified in the catalog Modification of parts of the actuator or replacement of components with different an...

Страница 8: ...ambient temperature 25 C without risk of internal parts overheating 10 10 100 Linear drive Fi Acme screw ATL series 30 Ball screw BSA series 100 For the proper operation of acme screw linear actuators...

Страница 9: ...INSTALLATION AND MAINTENANCE OF THE PRODUCT BEFORE TO PROCEED TO THE ELECTRIC CONNECTION MAKE SURE THE SUPPLY VOLTAGE IS TURNED OFF BEFORE TO TURN ON THE MOTOR MAKE SURE THE ELECTRIC CONNECTIONS ARE...

Страница 10: ...d fixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the stop positions simply release the grub screw on t...

Страница 11: ...se refer to the product catalogue or to the check sheet supplied with the actuator When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give th...

Страница 12: ...EED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection cla...

Страница 13: ...le length 1 3 m Enclosure rating IP 55 The rotary encoder ENC 4 must be connected to the electric control circuit as shown in the following WIRING DIAGRAM 6 5 Rotary encoder GI 2X THE ROTARY ENCODER G...

Страница 14: ...bi directional Resolution 100 or 500 pulses per revolution Output PUSH PULL 2 channels A and B phase difference 90 channel ZERO Input voltage 5 24 V DC No load current 100 mA Max commutable current 50...

Страница 15: ...ms Figure 6 3 Electric wiring diagrams to power supply a AC 3 phase motor b AC 1 phase motor c DC motor Figure 6 4 Electric wiring diagrams to motor terminal board a AC 3 phase motor b AC 1 phase moto...

Страница 16: ...F LOCKING BEFORE TO APPLY ANY AXIAL LOAD ON THE PUSH ROD LOCK THE INPUT SHAFT OR USE THE MOTOR BRAKE ALL MECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSO...

Страница 17: ...AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 9 Installation of rod end fitting elements To install a mounting element on the rod end threaded bore BA use a wrench flat on the rod end to counterhold the lo...

Страница 18: ...d Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the current actua...

Страница 19: ...T LUBRICANT SHOULD BE USED PLEASE CONTACT SERVOMECH BEFORE PROCEED IN CASE OF CUSTOM PRODUCT EXECUTION THE LUBRICANTS COULD BE DIFFERENT FROM THE STANDARD ABOVE TO KNOW THE TYPE OF LUBRICANT PLEASE RE...

Страница 20: ...es as shown on Fig 9 2 Grease nipple type DIN71412 M6 Figure 9 2 Linear drive relubrication of ATL BSA 30 40 Apply the grease quantity indicated in Tab 9 1 with several partial quantities Travel over...

Отзывы: