2

 

 

WARNING

 

 
These  units  are  capable  of  delivering  potentially  lethal  voltage  when 
connected  to    a  power  supply  and  are  to  be  operated  only  by  qualified 
technically trained personal. 
 
Please  read  the  entire  operator’s  manual  thoroughly  before  operating  this 
unit. 
The  BlueLine  vertical  electrophoresis  systems  are  designed  to  give  long 
service  and  reproducible  results  in  your  laboratory.  A  few  moments  spent 
reading  these  instructions  will  ensure  that  your  expectations  are  reflected  in 
the successful use of the apparatus. 
 

 

 
First  check  that  the  apparatus  has  been  received  complete  and  undamaged  following 
shipment.  Any faults or losses must be notified to responsible 

SERVA Electrophoresis 

GmbH

  distributor  immediately.

  SERVA  Electrophoresis  GmbH

  Heidelberg  cannot 

accept responsibility for goods returned without prior notification. 
 
 
Refer to the packing list and check that all components and accessories are present. 

 
 
 
Warranty is 12 months from the date of delivery. 
Please retain all packaging materials until the warranty period has expired. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ver. 02/13 

DOMINIQUE DUTSCHER SAS

Содержание BlueVertical PRIME

Страница 1: ...STRUCTION MANUAL BlueVertical PRiME Vertical Electrophoresis Chamber SERVA Electrophoresis GmbH Carl Benz Str 7 D 69115 Heidelberg Phone 49 6221 138400 Fax 49 6221 1384010 e mail info serva de http ww...

Страница 2: ...hat your expectations are reflected in the successful use of the apparatus First check that the apparatus has been received complete and undamaged following shipment Any faults or losses must be notif...

Страница 3: ...ral care and maintenance 6 4 3 Gel and buffer volumes running conditions 6 4 4 Performing electrophoresis 7 4 4 1 Insertion of pre cast gel cassettes into the inner core running unit 7 4 4 2 Sample lo...

Страница 4: ...nstruction All acrylic joints chemically bonded Doubly insulated cables rated safe up to 1000 volt Gold plated electrical connectors corrosion free and rated safe up to 1000 volt Safety lid with integ...

Страница 5: ...removing the safety cover Do not attach the safety lid to the internal gel running unit while it is out of the bottom buffer chamber Do not exceed the maximum operating voltage or current see Table 1...

Страница 6: ...ble1 The running conditions Table 2 vary according to the number of gels and their composition The current required will increase in proportion to the number of gels providing that the voltage is not...

Страница 7: ...he precast gel cassette into the inner core running unit When running only one gel a dummy plate is required on the opposite side to retain the required buffer level Place the gel running unit into th...

Страница 8: ...ctrophoresis Close the safety lid firmly making sure that the electrical connectors form a good contact Connect the electrophoresis apparatus to the power pack and connect the power pack to the mains...

Страница 9: ...rode connectors with tissue Ensure that the connectors are clean and dry before usage or storage see chapter 4 2 For further information about the SERVA BlueLine please contact the technical service o...

Страница 10: ...43277 SERVAGel TG PRiME 8 16 Tris Glycine Gel 8 16 12 43279 10 43280 2D 43281 SERVAGel TG 8 Tris Glycine Gel 8 Available upon request please inquire 12 43208 10 43209 SERVAGel TG 10 Tris Glycine Gel...

Страница 11: ...DS Electrophoresis Buffer 20x 42560 Buffers for native PAGE SERVA Tris Glycine Native Sample Buffer 2x 42528 SERVA Tris Glycine Native Electrophoresis Buffer 10x 42530 Native Anode Buffer for BN CN 10...

Отзывы:

Похожие инструкции для BlueVertical PRIME