Temperature control:

The temperature values for the Comfort-1, Comfort-2, Eco and Antifreeze modes are automatically 

calculated and cannot be directly modified by the user. The reference temperature is always 

indicated on the display together with the symbol representing the selected operating mode.

NOTE: 

The temperature measured by the sensor inside the product always indicates the ambient 

temperature in the immediate vicinity of the product and may differ from the temperature 

measured with other instruments in other areas of the room. This difference may depend on 

various factors, 

such as:

- The installation position: some areas of the room may be affected by currents or warm air pockets 

that can change the sensor measurement;

- The installation on an external perimeter wall, which is normally colder than internal walls, may 

result in a lower temperature measurement than the actual room temperature;

- Unstable conditions: each evaluation must be made under stable operating conditions. For this 

reason the Comfort temperature should not be changed before 60 minutes have elapsed since the 

previous modification. 

- In fact, it is not possible to assess whether the room temperature is correctly maintained by the 

product if the temperature level is continuously modified in a short period of time.

NOTE 

If the difference between the set temperature and the ambient temperature is detected in 

stability conditions, calculate this difference and then increase or decrease the comfort temperature 

level on the product of the exact calculated difference value.

Sirio 8

Содержание Sirio S2028

Страница 1: ...Operating Installation Manual Serene Model S2028 9 Convection Panels Model S2028 1000 Watts W 650 mm Model S2029 2000 Watts W 1050 mm...

Страница 2: ...use Do NOT touch hot surfaces or moving parts Do NOT cover the grilles or place any object or material up against the unit as this may block entry or exhaust of air Do NOT probe any opening To ensure...

Страница 3: ...ing Fix the convector in horizontal position with the air outlet grill upward This convector is fitted with a double electrical insulation circuit class II and therefore does not require earth connect...

Страница 4: ...roduct to the bracket until the lower hooks of the bracket are inserted in the slots on the rear panel as shown in figure 4 below Rotate the upper part of the product towards the wall until it locks m...

Страница 5: ...description The convector is equipped with an on off button on the right side When the product is switched off the internal electrical components will no longer activated The following controls are in...

Страница 6: ...be cancelled We recommend using it only if you do not use the product for a long time and instead use the ON STAND BY button on the control panel in the event of a short operating interruption of the...

Страница 7: ...Operating modes Sirio 6...

Страница 8: ...Special functions Sirio 7...

Страница 9: ...ts or warm air pockets that can change the sensor measurement The installation on an external perimeter wall which is normally colder than internal walls may result in a lower temperature measurement...

Страница 10: ...Date and time setting Weekly programming Sirio 9...

Страница 11: ...Weekly programming cont Sirio 10...

Страница 12: ...Troubleshooting Information for EU and UK Sirio 11...

Страница 13: ...Sha Wan Kowloon Hong Kong NEW ZEALAND t 64 3 344 5550 ff 0800 437 264 e nzenquiry serene ind com w www serene ind com PO BOX 33501 Barrington Christchurch 8024 AUSTRALIA e auenquiry serene ind com w w...

Отзывы: