background image

 

 | 8  

 

 

 

 

3-Hour Timer Mode: 

 
  In this mode the heater works on a 3-hour countdown timer that shuts the    
  heater off after 3 hours of operation.  

 
 
 

To restart the timer at any time

 
 1.   Simply touch POWER. 

 2.

   

Simultaneously touch and 

hold for 1 second 

the 

(

+

) and (

-

)

 controls.

 

      

 A blue indicator will begin flashing.     

 

  

 3.

   

The 3 hour countdown timer is now set and after 3 hours the heater 

 

  

will turn OFF automatically.

 

 

 4.    Press the 

POWER 

button and the heater will operate.                                                                                                                                 

 
 
Safety Cutout 

 
Your Serene Wall Fan Heater is fitted with an auto-reset thermal cutout and a 
fusible link. 
Either of these devices will automatically switch off the elements and the 
motor, should the unit reach an abnormal temperature.  

 
Should this occur, disconnect the heater from power supply, check for 
blockage of the air inlet and outlet, and use a vacuum cleaner to clean 
if necessary. 
 

 
 

Содержание Optima S2055

Страница 1: ...1 S2055 6 Wall Mount Space Heater with Cooling Fan Installation and Operating Manual Optima...

Страница 2: ...ree performance it is recommended that on a regular basis the unit be isolated from the power supply and a vacuum cleaner used to remove dust and fluff from the inlet and outlet grilles Do NOT allow t...

Страница 3: ...h POWER on the control panel and the adjacent blue LED will light SETTING THE HEAT CONTROL THERMOSTAT To set the electronic thermostat at the required setting press the selector buttons as follows To...

Страница 4: ...second the and controls A blue indicator will begin flashing The 3 hour countdown timer is now set and after 3 hours the heater will turn OFF automatically 3 FAN ONLY MODE Optima has a very powerful...

Страница 5: ...controller falls below 5 C To set the heater to Freeze Guard setting Press the freeze symbol on the left side of the control panel until the Red Freeze Guard indicator is lit 5 SELECTOR BUTTON Touch...

Страница 6: ...ched by a person in the bath or shower The minimum required distance from the heater to any floor is 150mm The minimum required distance from the heater to any adjacent wall is 200mm The heater MUST b...

Страница 7: ...ter against the wall and locate the mounting screws ensuring that the heater is level and the minimum distance between the heater and the adjacent surfaces are adhered to 3 Pull the heater gently down...

Страница 8: ...imer is now set and after 3 hours the heater will turn OFF automatically 4 Press the POWER button and the heater will operate Safety Cutout Your Serene Wall Fan Heater is fitted with an auto reset the...

Страница 9: ...d outlet grilles Ensure the heater is dry before turning the mains power supply to the heater back on Specifications Style Surface Mounted Model S 2055 S 2066 Height 272mm 272mm Width 525mm 590mm Dept...

Страница 10: ...ristchurch 8024 AUSTRALIA e auenquiry serene ind com w www serene ind com HONG KONG t 852 2325 3210 f 852 2325 3166 e info serene ind com w www serene ind com 1010 10th Floor Block A Alexander Industr...

Страница 11: ......

Отзывы: