Installation

Installation must be performed by a licensed electrician

This appliance MUST be installed in accordance with relevant wiring rules and 

regulations which cover installation of appliances and accessories in damp 

situations, such as bathrooms, showers, laundries and other areas, fixed water 

containers according to local safety regulations.

Distances

The heater must be mounted a minimum distance 

of

:

1800mm from floor level

200mmm below the ceiling

250mm from adjacent wall

500mm between the heater and any objects 

immediately below it.

Important

The heater must NOT be located immediately below a socket outlet.

The heater is to be installed so that switches and other controls cannot be touched by a 

person in the bath or shower.

Содержание S207T

Страница 1: ...Serene S2078 Serene Wall Mounted Fan Heater Specification Operating Instructions Model S207T Serene Wall Mounted Fan Heater with optional Electronic Timer Model S207T AU and NZ only ...

Страница 2: ...cerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do NOT use this appliance other than for its intended use Use this appliance only with the voltage specified on the rating label Be very careful not to touch hot surfaces or moving parts Do NOT cover the grilles or place any object or material up ag...

Страница 3: ...ies and other areas fixed water containers according to local safety regulations Distances The heater must be mounted a minimum distance of 1800mm from floor level 200mmm below the ceiling 250mm from adjacent wall 500mm between the heater and any objects immediately below it Important The heater must NOT be located immediately below a socket outlet The heater is to be installed so that switches an...

Страница 4: ...he timer no longer operates Air is drawn through the inlet grill in the top cover of the heater by the fan blown over heating elements and then blown out through the front grille into the room The heater can be controlled by a directly installed wall switch or the pull cord switch The heat output is regulated by an automatic pre set step down thermostat which will reduce the output from 2000 Watts...

Страница 5: ...e ind com Suite 1010 10F Block A Alexander Industrial Building 62 King Lam Street Cheung Sha Wan Kowloon Hong Kong SAR NEW ZEALAND t 64 3 344 5550 f 0800 437 264 Freefax e nzenquiry sereneind com w www serene ind com PO BOX 33501 Barrington Christchurch 8024 AUSTRALIA t 1800 844 942 e auenquiry serene ind com w www serene ind com UNITED KINGDOM and EUROPE t 44 01924 481053 e ukenquiry serene ind c...

Отзывы: