SW-ESW01N QIG V0.5
3
Z-Wave Command Classes
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_METER_V3
COMMAND_CLASS_NOTIFICATION_V4
Association
Support grouping identifier = 1
Support one group with 1 nodes.
All triggering report will be sent to the associated nodes.
Notification
Event type:
OCP:0x06
OVP:0x07
Notification type:
Power management:0x08
Devices From Multiple Vendors In One Network
SW-ESW01N can be included and operated in any Z-Wave network with other Z-Wave certified devices
from other manufacturers and/or other applications. All non-battery operated nodes within the network will
act as repeaters regardless of vendor to increase reliability of the network.
Z-Wave Configuration
Configuration
Parameter
Function
Size
(Byte)
Configuration
Value
Default
Setting
Description
1
Relay state when power up
1
0~2
0
0 : Last relay state
1 : Relay on
2 : Relay off
2
Auto report relay state
1
0~1
1
0 : Disable
1 : Enable