Save this instruction sheet. It contains important technical data, which will be useful for future reference.       

Operation 

          

           

 

1.

 

On/Off  and Pairing Button 

2. On/Off , Pairing and alarm LED (Green) 

 

Installation 

1.

 

Put the SW-ESW01N into a wall receptacle. Make sure the receptacle is working properly. If it is controlled by a wall switch, 
make sure it is set to ON all the times. 

2.

 

Attach the appliance to the SW-ESW01N and make sure the load does not exceed 15A 

 

Device Functions 

The table below summarizes Z-Wave related functions supported by the energy switch. 

Function Description 

Add(Inclusion) 

1.

 

Put the Z-Wave controller into "Add (Inclusion)" mode. 

2.

 

Power on the device. 

3.

 

The LED is blinking while scanning the network and. This process may    

take up to 30 seconds. (In the meanwhile, our device will send its NIF.) 

4.

 

If the add process is successful, the LED will turn off and restore to relay state. 

If the process failed, press the On/Off button once and the device will be in auto add 
mode again.  

Remove(Exclusion) 

1.

 

Set the Z-Wave controller to "Remove (Exclusion)" mode. 

2.

 

Press the On/Off  button three times within two seconds. 

3.

 

The LED will be blinking for one second.

 

(In the meanwhile, our device will send its 

NIF.) 

Note 1: if the Remove process is successful, the node ID will be cleared and the device 
will be in auto add mode. 

Note 2:Relay state default off 

Reset to Factory Defaults 

1.

 

Press the On/Off button 4 times within two seconds and hold the 4th press until the 
LED lights up.  

2.

 

The LED will turn off after three seconds. The node ID will be cleared and all 
settings will be reset to factory defaults. 

3.

 

The device will be in auto add mode. 

Note :Relay state default off 

Meter 

The device support below metering scale. 
  -0x00  Accumulate power consumption (kWh) 
  -0x02  Power consumption (W) 
  -0x04  AC load voltage (V)  

-0x05  AC load current (A) 

  -0x06  Load power factor (PF) 

*LED will be blinking quickly every 0.1sec, if OCP(Over Current Protection) or OVP(Over Voltage Protection) kick in.  

Otherwise, the blinking speed will be normal every 0.5sec. 