![Sercel GRC ESP Series Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/sercel/grc-esp-series/grc-esp-series_field-installation-manual_1245816044.webp)
Doc No. 006-0211-00 Rev AD
Page 44 of 62
Updating SPS-1500 Using Tera Term - TTermpro
1. Open
TTERMPRO
2. Select
SERIAL BUTTON
3. Drop down box and select
USB SERIAL PORT and COM PORT NUMBER
found under CONTROL PANEL/DEVICE MANAGER/PORTS.
4. OK
5.
SETUP MENU
then
SERIAL PORT
. See Figure 39.
a. PORT: Select Com Port
b. Baud Rate: 9600
c. DATA: 8 Bit
d. PARITY: NONE
e. STOP: 1 BIT
f. FLOW CONTROL: NONE
6. Select OK
Figure 39 TTERMPRO Serial Port Setup.
7.
Depress
SHIFT-U
while powering up the SPS-1500. You should see the screen
in Figure 40.
Содержание GRC ESP Series
Страница 1: ... ESP Monitoring System 0 12 11 3 1 ...