Data Pro
P/N 10029355 Rev AE
Operation Manual
Page 44 of 92
8.6.4.4 Safe Volt
The
‘Safe Voltage
’ prevents the SPS-1500 from operating if a high imbalance voltage is present on the
gauge input line to the SPS-1500. This protects the electronics from overloading the signal when trying
to operate over the imbalance.
The recommendation is to keep ‘
Safe Volt
’
in
‘Enabled’
state. The user
can enable or disable the ‘
Safe Voltage
’
with the following menu steps:
Menu
Interface Setup
Interface For Gauges
Config
Safe Volt
Edit
8.6.4.5 AutoA (Auto Analyze)
The
‘Auto Analyze’
feature allows the SPS-1500 to optimize the drive voltage for the tool by stepping
and analyzing the voltage on startup. The user can enable or disable the
‘Auto Analyze’
feature thru
below menu steps:
Menu
Interface Setup
Interface For Gauges
Config
AutoA
Edit
The recommendation is to keep
‘Auto Analyze’
in
‘Enabled’
state.
8.6.4.6 AutoV (Auto Volt)
The ‘
Auto Volt’
feature adjusts the line voltage while running to optimize the tool current for best
communication. The SPS-1500 adjusts the tool voltage at the end of every downhole tool
communication packet. The user can enable or disable the ‘
Auto Volt’
feature with the following menu
steps:
Menu
Interface Setup
Interface For Gauges
Config
AutoV
Edit
The recommendation is to keep
‘Auto Volt’
in
‘Enabled’
state.
8.6.4.7 AutoB (Auto Baud)
The ‘
Auto Baud’
feature compensates for gauge communication timing. The SPS-1500 monitors bit
timing on every transmitted byte from the ESP gauge. The SPS-1500 baud clock adjusts to match the
gauge bit timing during the ‘
Sync
’ packet.
The user can enable or disable the
‘Auto Baud’
feature with the following menu steps:
Menu
Interface Setup
Interface For Gauges
Config
AutoB
Edit
The recommendation is to keep ‘
Auto Baud’
in
‘Enabled’
state.
8.6.4.8 Max Baud
Setting the maximum Baud on the SPS-1500 can eliminate Baud rate errors from the gauge. It is
common to see
‘Baud Fast’
errors during the line analysis. The application displays the default,
minimum and maximum baud values on the configuration screen.
The user can change the
‘Max Baud’
via below menu steps:
Menu
Interface Setup
Interface For Gauges
Config
Max Baud