3.2 EARTH CONNECTION
Page 9/16
3.3 MOTOR CONNECTIONS
The connections differ depending on whether the motor (viewed from inside the gate) is positioned on the right
(factory setup) or on the left.
MOTOR ON THE RIGHT (FACTORY SETUP)
MOTOR ON THE LEFT
To connect the motor on the left-hand side of the
gate, swap the following connections:
5 with 6
15 with 16
CR/42/24
5 6
15 16 17
BLACK
BLUE
BROWN
CLOSE
OPEN
3.4 LED SIGNALS
LED
FCC
FCA
FOTO
STOP
PED
START
ON
OFF
FUNCTION
Opening limit switch
Closure limit switch
Photocell
STOP button
PEDESTRIAN button
Open/Close button
Photocell clear
Stop button in normal status
Pedestrian button pressed
Open/Close button pressed
Gate close or in intermediate
position (NC contact)
Gate completely closed
(NO contact)
Gate completely open
(NO contact)
Photocell obscured
(obstacle present)
Stop button pressed
Pedestrian button in normal status
Open/Close button in normal status
DL8
Programming/Test
- Flashing light to show programming mode has been accessed
- High frequency flashing light to indicate faults encountered during the
motor control test
DL9
Encoder
During gate movement, indicates encoder pulse reception
POWER SUPPLY
CABLE
230 V~
YELLOW/GREEN
CABLE
MOTOR
CONNECTION
TERMINAL
Gate open or in intermediate
position (NC contact)
SIN
C
E
1
96
5
M
E
R
C
U
R
IO
/5
2
4
A
I
E
CONNECTION TERMINAL
WITH FUSE HOLDER
Sensitive edge: in normal status
FOTO-1
Opening photocell
or sensitive edge
Photocell clear
Photocell obscured
Sensitive edge: pressed