Technical Data:
Height:
50.8 cm (20 in.)
Width:
16.6 cm (6.5 in.)
Depth:
18.6 cm (7.3 in.)
Volume:
approx. 3.3 l (0.8 US gal.)
Pump:
NP 1600
220 – 240 V ~ 50 Hz, 20 W
max. 40°C (104°F)
Hmax:
1.2 m (3.9 ft.)
Qmax:
1,400 l/h (369 US gal./h)
IPX8:
up to 1 m (3.3 ft.) water depth
Troubleshooting:
Spare parts:
Rotor with pinwheel
Ceramic shaft with rubber bearings
Pump NP 1600 (complete)
Flotate cup with cover
O-ring seal for outlet
Disposal of the unit:
Waste electrical and electronic equipment (WEEE)
must not get into domestic waste!
If ever the unit cannot be used anymore, the consumer
is legally obliged to hand in waste electrical and elec-
tronic equipment (WEEE) separately from domestic
waste, e.g. at a collection point of his community/his
district. This ensures that waste electrical and elec-
tronic equipment (WEEE) is expertly processed and
that negative effects to the environment are avoided.
Therefore electrical and electronic
equipment bears the following symbol:
Warranty:
When following the directions for use, the sera marin
Protein Skimmer 600 S will perform reliably. We are lia-
ble for the freedom from faults of our products only
within legal regulations beginning with the purchase
date.
We are liable for complete flawlessness at delivery.
Should usual wear and tear occur by use as intended
by us, this is not considered a defect. Warranty claims
are also excluded in this case. This particularly refers to
the running unit (rotor, shaft, rubber bearings) and the
hoses.
In every case of a defect we recommend that you con-
sult the specialized retailer where you purchased the
unit. He will be able to judge whether it is actually a
warranty case. In case of sending the unit to us we will
unnecessarily have to charge you for occurring costs.
Any liability because of contract breach is limited to
intent or gross negligence. sera will be liable in case of
slight negligence only in case of injuries to life, body
and health, in case of essential contractual obligations
and with binding liability according to the product lia-
bility code. In that case, the extent of liability is limited
to the replacement of contractually typically foreseea-
ble damages.
Problem
Possible cause
Troubleshooting
Insufficient air intake rate
Intake valve (4.19) insufficiently o-
pened
Open intake valve (4.19) further
Air hose (4.17) is encrusted with
lime or dirty
Clean
Intake nozzle (4.16) on the pump is
dirty
Pull off and clean
Pump performance is too low
Clean rotor and shaft
Foam too moist/
too much foam
Water level within the unit is too
high
Open flow adjustor (4.4) further
Too much air
Close intake valve (4.19) further,
first try to adjust with the flow
adjustor (4.4)
Foam too dry/
very viscous foam
Water level within the unit is too
low
Slightly reduce flow rate at the flow
adjustor (4.4)
Insufficient pump performance
Clean rotor, shaft and intake nozzle
Insufficient foam formation
Insufficient amount of air
Open intake valve (4.19) further
Foam formation too strong, very
brownish flotate, very sticky foam
Water strongly polluted
Partial water change, feed less
see: Insufficient foam formation
Increase flotate moisture
Foam formation breaks down
Feeding fatty food (fish, mussels)
Foam formation will begin again
after a few hours
Air intake congested
Clean air intake or open further
1 m
(3.3 ft.)