Air driven diaphragm pump
Pompe pneumatique à membrane
Operating instructions
Notice de mise en service
20
www.sera-web.com
Subject to technical modifications!
TA 312
Rev.
21 en
08/2018
EN
When used to pump hazardous media, provide a spray guard
on the air driven diaphragm pump as illustrated.
Under some circumstances it can happen that the medium
leaks out of the pump during and following a fault condition.
Leaked medium must be collected and properly disposed of.
CAUTION !
If a diaphragm rupture is not immediately recognised and
aggressive media are used, it can happen that these
media enter the air circuit and are blown into the
environment through the air outlet (noise absorber).
If not protective measure is installed:
RISK OF SEVERE HEALTH AND ENVIRONMENTAL
CONSEQUENCES!
8
Commissioning
Prior to start-up, check whether the suction and pressure lines
have been properly installed.
Suction side
= Inlet
Pressure side = Output
Open the shut-off fittings on the pump (suction and pressure
connection).