8. Maintenance

To ensure perfect functioning, it is recommended to regularly check the gas precharge pressure and/or to control the 

pointer deflection every month:

Maintenance intervals:

 

 The gas precharge pressure must be checked and re-adjusted after each re-installation, or repairs. See Chapter 

„Start-up“ for the precise procedure.

 

 Generally, it is required to check the gas precharge pressure after each modification of the system parameters (filling 

of the gas - / air cushion according to Chapter „Start-up“).

 

 Check the filling device regularly for leaks.

 

 Regular checks: 

 

Yearly visual check 

 

Every 2 years – a pressure check using water with the 1.43-fold of the nominal pressure. For this purpose, 

disassemble the pulsation damper and test under pressure in a place which corresponds to the regulations 

for prevention of accidents:

The operator is obliged to document these checks.

NOTE!

9. Spare- and wearing parts

Diaphragm pulsation dampers of type series 810.1 do not have replaceable wearing parts. In case of a diaphragm rupture 

the complete pulsation damper is to be exchanged.

The following parts are considered as spare parts of the pulsation damper:

 

 Filling- and pressure measuring device

10. Shut-down

 

 Shut-down the pump/system and secure it against restarting!

 

 Make sure that all pipes with pulsation dampers are pressureless!

 

 Drain the pulsation dampers and the connected pipes using drain cocks!

 

 Remove residues of the pumped medium from the pulsation damper by rinsing it with a compatible flushing agent!

 

 Reduce gas- / air pressure (gas cushion).

 

 The pulsation damper can then be removed from the pipe.

11. Disposal

Shut-down system. Please see “Shut-down”.

Содержание 810.1 Series

Страница 1: ...future use Please state here the exact type and serial number of your pulsation dam per can be read off the type plate on the pulsation damper Type Serial No These data are important in case of queri...

Страница 2: ...2 www sera web com Technical modifications reserved TA 346 Rev 8 en 07 2013 Pulsation Damper with Separating Diaphragm 810 1 Operating Instructions EN...

Страница 3: ...6 2 4 Intended use 6 2 5 Approved installation maintenance and operating personnel 7 2 6 Personal protection for maintenance and service 7 2 7 Operating conditions of the pulsation damper 7 3 Transpor...

Страница 4: ...re side 1 General 1 1 General user information 1 2 Symbols and notes used in these operating instructions Special notes in these operating instructions are marked with text and danger symbols Notes Da...

Страница 5: ...medium The owner must take corresponding accident prevention measures to protect opera ting personnel from danger through the pumped media used CAUTION 1 3 Marking of notes on the product Symbols whi...

Страница 6: ...tions must be discussed with sera beforehand Criteria for proper operation of the pulsation damper Max pressure of the pulsation damper Observe characteristics of the pumped medium fluid group please...

Страница 7: ...dinance on Hazardous Substances GefStoffV 14 Safety Data Sheet and relevant national safety regulations for the pumped medium and the operating condi tions of the pulsation damper must strictly be adh...

Страница 8: ...ly be opened when the pul sation damper is installed Proper storage increases the service life of the pulsation damper and comprises prevention of negative influences such as heat humidity dust chemic...

Страница 9: ...ll as on the density of the pumped medium Depending on the system configuration these pressure peaks may lead to cavitation on the suction side On the pressure side also either excess supply or inadmi...

Страница 10: ...Manometer 63 0 16 bar sheet steel casing copper coated measuring system glycerine damped 1 Material Max operating pressure bar Article No PP 10 37600675 1 4571 10 37600438 Filling pump FLP2 for filli...

Страница 11: ...10 10 0 16 0 8 1 4571 FPM 37603724 Butyl 37603720 810 1 0 32 10 10 0 32 1 3 1 4571 FPM 37603725 Butyl 37603721 810 1 0 75 10 10 0 75 2 8 1 4571 FPM 37603726 Butyl 37603722 810 1 2 0 10 10 2 4 0 1 457...

Страница 12: ...74 30 810 1 0 32 10 G 1 2 257 243 14 93 30 810 1 0 75 10 G 1 2 288 274 14 212 41 810 1 2 0 10 G 3 4 338 324 18 160 46 Type G H H1 h D SW mm 810 1 0 16 180 G 1 2 124 225 14 74 30 810 1 0 32 160 G 1 2 1...

Страница 13: ...way that it is easy to access and free from vibrations The attached pipes must not transmit any mechanical tensions to the pulsation damper The weight of the pulsation dampers may only be applied to...

Страница 14: ...urning the spindle Screw off the filling and pressure measuring device Tighten hexagon socket 1 2 Bleeding air 810 1 10 The filling and pressure measuring device 1 for operating pressure up to 10 bar...

Страница 15: ...h adjustment 2 Dosing pump 3 Mean value 4 Manometer 5 Pressure measuring filling device 6 Gas cushion 7 Diaphragm 8 Pumped medium Carry out the following steps when this mean value is reached or excee...

Страница 16: ...of the nominal pressure For this purpose disassemble the pulsation damper and test under pressure in a place which corresponds to the regulations for prevention of accidents The operator is obliged t...

Страница 17: ...e was filled in correctly and completely by authorized and qualified personnel NOTE All industrial companies are obligated by the legal provisions for occupational health e g the workplaces ordinances...

Страница 18: ...O Special security arrangements with respect to health or water hazardous media are in the further handling not required required The following safety precautions regarding rinsing residual liquids an...

Страница 19: ...19 TA 346 Rev 8 en 07 2013 Technical modifications reserved www sera web com Pulsation Damper with Separating Diaphragm 810 1 Operating Instructions EN NOTES...

Страница 20: ......

Отзывы: