Sera 810.1 Series Скачать руководство пользователя страница 10

10

www.sera-web.com

Technical modifications reserved!

TA 346

Rev.

8

en 07/2013

Pulsation Damper with Separating Diaphragm

810.1

Operating Instructions

EN

4.4 Accessories

4.4.1 810.1-.../10

Filling- and pressure measuring device (mounted on pulsation dampfer)

 

Outlet cannot be detached during operation

 

Filling valve (with backflow function) (

1

)

 

PP-design: 

Manometer Ø 63, 0-16 bar, plastic casing,  

copper-coated measuring system

 

1.4571-design: 

Manometer Ø 63, 0-16 bar, sheet steel casing,  

copper-coated measuring system, glycerine damped

1

Material

Max. operating pressure

(bar)

Article No.

PP

10

37600675

1.4571

10

37600438

Filling pump FLP2 for filling equipment

 

Filling pressure up to 7 bar

 

mit manometer

 

2 m hose

 

Coupling piece for air filling valve

Article No.

90009396

4.4.2 810.1-.../180 ... /100

Filling- and pressure measuring device

 

Manometer Ø 63, plastic casing,  

copper-coated measuring system

 

Outlet can be detached during operation and used again

 

2,5m filling hose

 

Connection M14x1,5

Material

Max. operating pressure

(bar)

Article No.

1.4571

25

37601674

100

37601673

250

30066005

Содержание 810.1 Series

Страница 1: ...future use Please state here the exact type and serial number of your pulsation dam per can be read off the type plate on the pulsation damper Type Serial No These data are important in case of queri...

Страница 2: ...2 www sera web com Technical modifications reserved TA 346 Rev 8 en 07 2013 Pulsation Damper with Separating Diaphragm 810 1 Operating Instructions EN...

Страница 3: ...6 2 4 Intended use 6 2 5 Approved installation maintenance and operating personnel 7 2 6 Personal protection for maintenance and service 7 2 7 Operating conditions of the pulsation damper 7 3 Transpor...

Страница 4: ...re side 1 General 1 1 General user information 1 2 Symbols and notes used in these operating instructions Special notes in these operating instructions are marked with text and danger symbols Notes Da...

Страница 5: ...medium The owner must take corresponding accident prevention measures to protect opera ting personnel from danger through the pumped media used CAUTION 1 3 Marking of notes on the product Symbols whi...

Страница 6: ...tions must be discussed with sera beforehand Criteria for proper operation of the pulsation damper Max pressure of the pulsation damper Observe characteristics of the pumped medium fluid group please...

Страница 7: ...dinance on Hazardous Substances GefStoffV 14 Safety Data Sheet and relevant national safety regulations for the pumped medium and the operating condi tions of the pulsation damper must strictly be adh...

Страница 8: ...ly be opened when the pul sation damper is installed Proper storage increases the service life of the pulsation damper and comprises prevention of negative influences such as heat humidity dust chemic...

Страница 9: ...ll as on the density of the pumped medium Depending on the system configuration these pressure peaks may lead to cavitation on the suction side On the pressure side also either excess supply or inadmi...

Страница 10: ...Manometer 63 0 16 bar sheet steel casing copper coated measuring system glycerine damped 1 Material Max operating pressure bar Article No PP 10 37600675 1 4571 10 37600438 Filling pump FLP2 for filli...

Страница 11: ...10 10 0 16 0 8 1 4571 FPM 37603724 Butyl 37603720 810 1 0 32 10 10 0 32 1 3 1 4571 FPM 37603725 Butyl 37603721 810 1 0 75 10 10 0 75 2 8 1 4571 FPM 37603726 Butyl 37603722 810 1 2 0 10 10 2 4 0 1 457...

Страница 12: ...74 30 810 1 0 32 10 G 1 2 257 243 14 93 30 810 1 0 75 10 G 1 2 288 274 14 212 41 810 1 2 0 10 G 3 4 338 324 18 160 46 Type G H H1 h D SW mm 810 1 0 16 180 G 1 2 124 225 14 74 30 810 1 0 32 160 G 1 2 1...

Страница 13: ...way that it is easy to access and free from vibrations The attached pipes must not transmit any mechanical tensions to the pulsation damper The weight of the pulsation dampers may only be applied to...

Страница 14: ...urning the spindle Screw off the filling and pressure measuring device Tighten hexagon socket 1 2 Bleeding air 810 1 10 The filling and pressure measuring device 1 for operating pressure up to 10 bar...

Страница 15: ...h adjustment 2 Dosing pump 3 Mean value 4 Manometer 5 Pressure measuring filling device 6 Gas cushion 7 Diaphragm 8 Pumped medium Carry out the following steps when this mean value is reached or excee...

Страница 16: ...of the nominal pressure For this purpose disassemble the pulsation damper and test under pressure in a place which corresponds to the regulations for prevention of accidents The operator is obliged t...

Страница 17: ...e was filled in correctly and completely by authorized and qualified personnel NOTE All industrial companies are obligated by the legal provisions for occupational health e g the workplaces ordinances...

Страница 18: ...O Special security arrangements with respect to health or water hazardous media are in the further handling not required required The following safety precautions regarding rinsing residual liquids an...

Страница 19: ...19 TA 346 Rev 8 en 07 2013 Technical modifications reserved www sera web com Pulsation Damper with Separating Diaphragm 810 1 Operating Instructions EN NOTES...

Страница 20: ......

Отзывы: