105
Trigon-6 User’s Guide
Appendix B: MIDI Implementation
Request Program Dump
Status
Description
1111 0000
System Exclusive (SysEx)
0000 0001
DSI ID
0010 1101
Trigon-6 ID
0000 0101
Request Program Transmit
0000 00vv
Bank Number, 0 - 9
0vvv vvvv
Program Number, 0 - 99
1111 0111
End of Exclusive (EOX)
The Trigon-6 will respond by sending out the Program Data in the format
described below in
Program Data Dump
.
Request Program Edit Buffer Dump
Status
Description
1111 0000
System Exclusive (SysEx)
0000 0001
DSI ID
0010 1101
Trigon-6 ID
0000 0110
Request Program Edit Buffer Transmit
1111 0111
End of Exclusive (EOX)
The Trigon-6 will respond by sending out the current Program edit buffer
in the format described below in Program Edit Buffer Data Dump.
Request Global Parameter Dump
Status
Description
1111 0000
System Exclusive (SysEx)
0000 0001
DSI ID
0010 1101
Trigon-6 ID
0000 1110
Request Global Parameter Transmit
1111 0111
End of Exclusive (EOX)
The Trigon-6 will respond by sending out the current values of Global
Parameters in the format described in
Global Parameters Data Dump
.