1.0 Operation 

The Model 700 Programmer consists of two envelope generators and three 
general-purpose voltage sources, all of which are connected to the synthesizer 
that is going to be controlled. Envelope 1 should be connected to the VCA, and 
Envelope 2 should be connected to the filter control input. The voltage sources 
are usually patched to three VCOs. The 700 also requires a gate signal. A switch 
trigger (Moog), or a gate and a trigger can also be connected when available. 
More detail for connection to individual synthesizers is contained at the end of 
this manual. 

1.1   Memory Selection 

There are eight PROGRAM SELECT pushbutton switches that select one of 
eight different programs. When selected, the corresponding LED indicator on the 
switch will light. The MEMORY BANK rotary switch can select one of eight 
different memory banks. Each memory bank contains a different set of eight 
programs; hence 64 (8 x 8) different programs can be selected at any time. The 
current bank and program numbers are displayed on LED numerical displays for 
quick reference. 

The current program can also be changed by an external signal input to the 
PROGRAM INCREMENT socket. The footpedal provided can be connected to 
this input, so that each time the footpedal is hit, the program will increment. Any 
other general-purpose pulse of sufficient duration (greater than 10 milliseconds) 
will also increment the program when connected to the PROGRAM 
INCREMENT. This input is de-bounced so that relatively noisy signals can still be 
used. The maximum frequency that can be used is approximately 20 Hz. The 
EDGE switch selects whether to increment the program on the rising edge of the 
signal (

) or on the trailing edge of the signal (

). The SEQUENCE LENGTH 

rotary switch is used to select how many programs to cycle through before 
resetting to program 1. That is, if the SEQUENCE LENGTH is set to 3, the 
program will cycle 1-2-3-1-2-3-1 etc. with each new pulse. When in the OFF 
position, the incoming pulses will be ignored, and no incrementing will take place. 
The pushbuttons are still active at all times, regardless of external pulses or the 
setting of the SEQUENCE LENGTH switch. 

Содержание 700

Страница 1: ...MODEL 700 PROGRAMMER OPERATIONS MANUAL Sequential Circuits Inc 1979 ...

Страница 2: ...nce 64 8 x 8 different programs can be selected at any time The current bank and program numbers are displayed on LED numerical displays for quick reference The current program can also be changed by an external signal input to the PROGRAM INCREMENT socket The footpedal provided can be connected to this input so that each time the footpedal is hit the program will increment Any other general purpo...

Страница 3: ...and re programmed with the current front panel settings Be careful not to destroy the wrong program The memory in the programmer is non volatile meaning that it retains its information even when power is removed This means that once a program is stored it will always be there no matter what happens to the programmer There are three penlight batteries that keep the memory active when AC power is re...

Страница 4: ...five octave range on your oscillators The VOLTAGE controls step in semitone steps when turned quantized which makes tuning extremely fast and easy The voltage steps in the programmer are very accurate but often times the oscillators in your synthesizer may not be Remember that if your synthesizer is out of tune normally it will be out of tune with the programmer Some synthesizers may require that ...

Страница 5: ... your second program and store it in another memory location Typically you will want to set up sounds that will be used together all in one memory bank so that switching from one to the other will be fast During performance the programmer will be in PLAYBACK mode and a simple push of a PROGRAM SELECT pushbutton is all that is required to change your synthesizer s sound 2 0 Programmer Notes 2 1 Occ...

Страница 6: ...Model 700 Programmer Operations Manual Sequential Circuits Inc 1979 PDF Version by the Emulator Archive 2002 Page 6 ...

Страница 7: ...ARD CV IN ENVELOPE 1 VCA ADSR CONTROL IN ENVELOPE 2 VCF ADSR CONTROL IN Set the VOLTAGE 1 VOLTAGE 2 VOLTAGE 3 and ENVELOPE 2 switches to the ADD EXT position Turn VOLTAGE 1 VOLTAGE 2 and VOLTAGE 3 controls fully counter clockwise and set the mode to VARIABLE Tune the three oscillators to the lowest note that you will need From now on do not change the tuning of the oscillators on the synthesizer m...

Страница 8: ...UDNESS SUSTAIN fully clockwise 6 DECAY switch on You are now ready to start setting up your programs Mini Moogs often require the programmer to be tuned to match exactly as described in section 1 4 Use the 440 oscillator as the reference for tuning rather than two oscillators When using the Mini in this set up the three oscillators cannot be used separately There is a fairly simple modification th...

Страница 9: ... of the OSCILLATOR CONTROL INPUT jack 5 Connect a 15 inch wire and a three inch wire to the output lug of the VOLTAGE 2 jack Label the long wire at the other end as VOLTAGE 2 6 Connect the other end of the short wire to the shorting lug of the VOLTAGE 3 jack 7 Connect a 15 inch wire to the output lug of the VOLTAGE 3 jack Label the other end of this wire as VOLTAGE 3 8 Replace the inside board 9 R...

Страница 10: ...Model 700 Programmer Operations Manual ...

Страница 11: ...d contacts the reliability is very good Viking also makes custom moulded cables to fit these connectors The specific receptacle part number that we will be using in the 700 is a TKR12 1017 that cost about 0 42 in 1000 quantity The pin contacts that will be used are TP 100AU costing about 0 08 each in 10 000 quantities 12 pins will be installed with one not assigned spare These pins are used with a...

Страница 12: ...ese signals are redundant with the normal back panel jacks and have identical operation The new Model 700 will also have individual scaling trimmers for the three output VOLTAGES with access holes in the panel This will allow in most cases the ability to do all interface trimming in the 700 without having to adjust the synthesizer When shipped they will be trimmed to exactly 1V OCT The deliveries ...

Страница 13: ...Model 700 Programmer Operations Manual ...

Отзывы: